Parameter Value Assignment
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
Para-
meter
No.:
Name
Description / explanation
selectable options
Factory
setting
min ... max
values
Pass-
word
0411
Output-block
signal
Supplementary parameter for “analog output”.
direct
1
Defines how a signal is transferred.
0 = direct
1 = absolute value
2 = inverted
3 = absolute value, inverted
0...3
0413
Output-block,
norm.
Supplementary parameter for “analog output”.
100.00 %
1
Normalization of the analog output 10 V correspond to the
value set here.
6.26 ...
200.00 %
0561
Output-block
Supplementary parameter for “analog output”.
0.. ±100 %
2
0 = 0 ... ±100 %
1 = +20 ... +100 %
0 / 1
0412
Output-block
offs.
Supplementary parameter for “analog output”.
0.00 %
1
Offset
-100.00 ...
100.00 %