![REXROTH RD 500 Series Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/rexroth/rd-500-series/rd-500-series_applications-manual_1449588155.webp)
RD 500 RD51
Inverter Technical Data
5-15
DOK-RD500*RD51*******-IB04-EN-P
Circuit Principle of Power Section, Size Class G (without SFT)
ext. fuse
Ground
+24 V
24 V-Power supply
X2
V2
PE
W2
U2
PE
X83
EW
SE
WS
24 V
SNT*
Inverter control
DC link
X155
WR
3
1
2
1 2
X80
+24V
4 5
å
EW
Ground fault transducer
SE
Current sensing
SNT* Switched-mode power supply
(not equipped at additional
function V1)
WS
Inverter control
WR
Inverter
T1
Control transformer
X1
C
D
DC link connection
L+
L-
PE
Starting lock-out
X5
2U1
2V1
3 1
V1 24 V Power supply
additional function
Device-variant
X80 Inverter with Stating lock-out
BS510008EN02.FH9
PE
Heat exchanger
PE
E1
X2.1
P1
V1
X2.2
M 3~
J
J
T1
ext. fuse
Power supply for inverter
with supply voltage
DC 530...670V: AC 400 V 50/60 Hz
DC 700V: AC 500 V 50/60 Hz
1)
1):
only for cooling type F
Fig.: 5-4 Circuit principle of power section, inverter size class G
Note:
When additional function V1 is used, module SNT is not
equipped. See Chapter 11.1.
Содержание RD 500 Series
Страница 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 275: ......