5-10
Inverter Technical Data
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
5.10 Technical Data SFT Motor inverter for Size Classes C, D
and E with Pulse frequency f
p
= 8 kHz
8 kHz
RD51.3
030
045
055
075
090
110
Rated motor output
1)
kW 22
37
45
55
75
90
Supply voltage DC 750 V (-15 % +5 %)
Output frequency Hz
0 - 500
Rated current
A
33
52
64
77
104
126
Peak current for t = 60 s A
43
69
83
100
135
163
t = 1 s A
56
91
108
131
177
213
t = 0.5 s A
66
107
128
155
209
252
Rated output S
N
kVA 29
46
56
68
92
111
Peak power for t = 60 s kVA 38
61
73
88
119
144
Ambient conditions, noise suppression level, interference immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0 – 40 °C operation, to
50 °C power reduction at 2.5 % per K)
Cooling air requirement m³ / s
0.1
0.2
0.4
0.4
0.4
0.4
Power loss kW
0.8
1.17
1.37
1.85
2.25
2.81
Radio int. sup. level / noise immunity
A 2 according to EN 55011 / EN 61800-3
Mechanical design
Size classes
C
C
D
D
E
E
Degree of protection
IP 20 according to EN 60529 (without connection terminals)
Weight of inverter for the various cooling types
L Forced air cooling kg
22
22
32
32
44
44
D Plug-through cooler kg 20
20
30
30
42
42
W Liquid cooling
See DOK-
RD500*SFT********-
PR0x-EN-P
1):
Max. permissible motor power based on 4-pin standard induction
motor 500 V
Содержание RD 500 Series
Страница 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 275: ......