No. Message in display
Meaning and possible cause
52 Error at hopper cover
The position of the hopper cover could not
be reached.
•
Blockage
•
Defective actuator
53 Defect at hopper cover
The hopper cover actuator cannot reach the
target value for the movement.
•
Blockage
•
Defective actuator
57 Error at hopper cover
The hopper cover actuator cannot reach the
target value for the movement.
•
Blockage
•
No position feedback
71 Impossible to reach disc speed
The spreading disc speed is not within the 5 %
target range.
•
Problem with oil supply
•
Proportional valve spring is jammed.
72 Error at SpreadLight
Power supply is too high; the operating lights
will be switched off.
73 Error at SpreadLight
Overload
74 Defect at SpreadLight
Connection error
•
Defective cable
•
Loose plug connector
75 Conveyor belt speed could not be reached
The conveyor belt has not reached the target
speed within 5 s.
76 Error at left pre-metering slider cylinder
The position at the right pre-metering slide
could not be reached.
•
Blockage
•
Hydraulics cylinder defective
77 Error at right pre-metering slider cylinder
The position at the right pre-metering slide
could not be reached.
•
Blockage
•
Hydraulics cylinder defective
78 AXENT empty
The hopper is empty.
7. Alarm messages and possible causes
AXENT ISOBUS
5901646
107
Содержание AXENT 100.1
Страница 6: ...Table of contents 6 5901646 AXENT ISOBUS...
Страница 21: ...2 3 Structural menu overview 2 Layout and function AXENT ISOBUS 5901646 21...
Страница 22: ...2 Layout and function 22 5901646 AXENT ISOBUS...
Страница 80: ...Fig 39 Button functions Level 1 Fig 40 Button functions Level 2 4 Operation 80 5901646 AXENT ISOBUS...
Страница 113: ......
Страница 114: ......