7
Alarm messages and possible causes
7.1
Meaning of the alarm messages
Various alarm messages can be displayed on the ISOBUS terminal display.
No. Message in display
Meaning and possible cause
1
Fault in dosing system, stop !
The motor of the metering system cannot reach
the specified target value:
•
Blockage
•
No position feedback
2
Max. outlet reached! Speed or application rate
too high
Metering slide alarm
•
The maximum metering opening is
reached.
•
The set application rate (+/- quantity)
exceeds the maximum metering opening.
3
Flow factor is outside limits
The flow factor must lie within a range between
0.40 and 1.90.
•
The newly calculated or entered flow
factor is outside this range
4
Hopper left empty!
The filling level sensor on the left reports
“empty.”
•
The left hopper is empty.
5
Hopper right empty!
The filling level sensor on the right reports
“empty.”
•
The right hopper is empty.
15 Memory full, Delete one private fertiliser chart
A maximum of 30 fertilizer types are stored in
the memory for the fertilizer charts.
16 Approach drop point Yes = Start
Safety request before the drop point is
automatically approached
•
Drop point setting in the menu Fertiliser
settings
•
Fast emptying
7. Alarm messages and possible causes
104
5901646
AXENT ISOBUS
Содержание AXENT 100.1
Страница 6: ...Table of contents 6 5901646 AXENT ISOBUS...
Страница 21: ...2 3 Structural menu overview 2 Layout and function AXENT ISOBUS 5901646 21...
Страница 22: ...2 Layout and function 22 5901646 AXENT ISOBUS...
Страница 80: ...Fig 39 Button functions Level 1 Fig 40 Button functions Level 2 4 Operation 80 5901646 AXENT ISOBUS...
Страница 113: ......
Страница 114: ......