When starting the spreading disc for the first time, the machine control adjusts the idling torque of the
system. See
7.1 Meaning of the alarm messages
.
If the alarm message is displayed repeatedly even though the transmission oil is warm:
•
Compare the installed spreading disc with the type entered in the Fertiliser settings menu. If
required, adjust the type.
•
Check the spreading disc for tight seat. Re-tighten the wheel nut
•
Check the spreading disc for damage. Replace the spreading disc.
Once the idle measurement has been completed, the machine control unit will set the idling time to
19:59 minutes in the display of the working screen.
u
Press
Start/Stop
.
The spreading starts.
The idle measurement runs in the background, even if the metering slides are closed. However,
no screen is shown on the display. However, no screen is shown on the display.
Once this idling time has expired, a further idle measurement is started automatically.
Fig. 47: Display of the idle measurement in the working screen
[1]
Time until the next idle measurement
In the case of a reduced spreading disc speed, no idle measurement can be executed if limited
border spreading or section reduction are activated!
5. Spreading operation with AXIS-PowerPack