background image

 
 
 

INSTALLATION 

 

 

 

final – public (B 

2012-08-09 – M20711-0e-ID-B.docx

 

 

ID ISC.MRU102-PoE / ID ISC.MRU102-USB 

Housed Version 

 

 

 

 

 

 

 

Содержание OBID i-scan UHF

Страница 1: ...INSTALLATION final public B 2012 08 09 M20711 0e ID B docx ID ISC MRU102 PoE ID ISC MRU102 USB Housed Version ...

Страница 2: ...t of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human To avoid...

Страница 3: ... former issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this may cause faulty operation of the reader The following figure formats are used 0 9 for decimal figures 0x00 0xFF for hexadecimal figures b0 1 for binary figures The hexadecimal value in brackets ma...

Страница 4: ...sembly and Wiring 8 3 1 Housed Versions 8 3 1 1 Dimensions 8 4 Connections 9 4 1 Antenna Terminal ANT1 10 4 2 Internal Antenna ANT4 10 4 3 Power Supply 11 4 3 1 Power Supply via X1 11 4 3 2 Power Supply via Power over Ethernet PoE 12 4 4 Ethernet Interface on X4 10 100Tbase 13 4 5 USB Interface on X3 Host Communication 14 5 Control and Display Elements 15 5 1 LED 15 6 Technical Data 16 7 Radio App...

Страница 5: ...OBID i scan UHF Installation ID ISC MRU102 PoE USB FEIG ELECTRONIC GmbH Page 5 of 21 M20711 0e ID B docx ANNEX A Accessories 20 ANNEX B Wall Mounting Kit ID ISC MS MR PR A 21 ...

Страница 6: ...are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its insta...

Страница 7: ...A connector for conduction of an external antenna ANT1 Addi tional an integrated antenna ANT4 is available The reader is designed for use in applications with small tag populations Maximum 10 tags at the same time into the antenna field can be processed The reader is available in two different versions Depending on the used version a connection to the Host System can either be made via the USB or ...

Страница 8: ... for an office environment It can be wall mounted in this case the wall mount kit should be ordered separately see Appendix ANNEX A1 Wall Mounting Kit ID ISC MS MR PR A NOTE Before any installation the intended position of the reader should be tested for its suitabili ty 3 1 1 Dimensions 145 85 LED 27 Figure 1 Dimensions of the housing version all dimensions are in mm ...

Страница 9: ...rs are available Figure 2 Connection overview displays the arrangement and the Table 2 Connectors shows which connector can be used for the different interface cable Figure 2 Connection overview Connector Description ANT 1 Antenna Terminal ANT1 Impedance 50Ohm X1 Power supply 12 24VDC X3 USB Interface X4 10 100Tbase Ethernet interface with RJ 45 PoE Table 2 Connectors ...

Страница 10: ...When connecting an antenna ensure that it does not exceed the permissible limits pre scribed by the national regulations for radio frequency devices 4 2 Internal Antenna ANT4 Additionally the reader is equipped with an internal antenna ANT4 The internal antenna supports far field transponders as well as near field transponders The internal antenna is located in the bot tom left corner of the housi...

Страница 11: ...ower supply only Power supply recommendations To take full advantage of the Reader performance you must use a sufficiently regulated and low noise power supply When using a switching power supply be sure that its internal switching fre quency is less than 300 kHz See also ANNEX A Accessories Feig Article No Part No Description 1688 002 00 ID NET 12V B EU Power Supply 95 265V AC Input Voltage with ...

Страница 12: ... connection NOTE It must be ensured that the reader is supplied with 42 5 V DC 48 V DC cable losses at least The maximum cable distance for Ethernet is 100m A connection of the PoE Port X4 to devices at outside building installation e g connected to the outside plants is not allowed It is recommended to use a shielded twisted pair STP CAT5 cable For detailed technical information regarding the 802...

Страница 13: ...hould be used This ensures a reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP IP protocol is that each device has a unique address on the net work All Readers have a factory set IP address Interface parameter can be configured via soft ware protocol e g ISOStart Network Address IP Address 192 168 10 10 Subnet Mask 255 255 255 0 Port 10001 DHCP OFF Table 7 Standard factory c...

Страница 14: ...he connection of the USB Interface The pinout is standar dized The data rate is reduced to 12 Mbit USB full speed A standard USB cable can be used Figure 5 USB interface for host communication NOTE The length of the USB cable can be a max of 5 meter It isn t allowed to use longer cables The reader must be powered with a external power supply even if it is connected to a high powered port ...

Страница 15: ...e The following Table 8 shows the default setting Abbreviation Description LED green RUN Turns on when the Reader is ready LED red LABEL Turns on when a transponder is detected Flashes if RF Warning red green alternating with 8Hz Temperature alarm short circuit on antenna output LED orange INITIALIZING Flashes during Reader initialization after power up Table 8 Default configuration of the LEDs ...

Страница 16: ...ight 200 g Protection Class IP 30 Colour ähnlich RAL 9018 Papyrusweiß ELECTRICAL DATA Power Supply ID ISC MRU102 USB ID ISC MRU102 PoE 12 V DC 24 V DC 12 V DC 24 V DC or PoE Power Consumption max 7 W Operating Frequency 860 MHz 960 MHz RF Power Max 500 mW 1 5 dB Antenna Connector 1 x SMA female 50 Ω 1 x integrated Antenna ANT4 Interfaces ID ISC MRU102 USB ID ISC MRU102 PoE USB Full Speed Ethernet ...

Страница 17: ...atures Anticollision RSSI Temperature Monitoring UMGEBUNGSBEDINGUNGEN Temperaturbereich Betrieb Lagerung 25 C bis 55 C USB 25 C bis 45 C PoE 25 C bis 85 C Relative Luftfeuchtigkeit 5 bis 95 nicht betauend APPLICABLE STANDARDS Radio Regulation Europe USA Canada EN 302 208 FCC 47 CFR Part 15 IC RSS Gen RSS 210 EMC EN 301 489 Vibration EN 60068 2 6 10 Hz bis 150 Hz 0 075 mm 1 g Shock EN 60068 2 27 Ac...

Страница 18: ...1 0e ID B docx 7 Radio Approvals 7 1 Europe CE When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guideline 1999 E6 dated March 99 Equipment Classification according to ETSI EN 301 489 Class 2 ...

Страница 19: ...OBID i scan UHF Installation ID ISC MRU102 PoE USB FEIG ELECTRONIC GmbH Page 19 of 21 M20711 0e ID B docx 7 2 Declaration of Conformity ...

Страница 20: ...e 0 C to 40 C 3886 000 00 ID NET 12V B GB Power Supply 95 265V AC Input Voltage GB UK Plug with angular DC Plug 2 5mm 5 5mm Output 12 V DC 700mA Ambient Operating Temperature 0 C to 40 C 3887 000 00 ID NET 12V B US Power Supply 95 265V AC Input Voltage US Plug with angular DC Plug 2 5mm 5 5mm Output 12 V DC 700mA Ambient Operating Temperature 0 C to 40 C 3842 000 00 ID NET PoEI13W A Power over Eth...

Страница 21: ...it ID ISC MS MR PR A The wall mounting kit can be used to attach the Reader to a flat surface Remove the screws from the back side of the Reader Attach the individual wall hangers using the screws supplied with the mounting kit Figure 6 Mounting wall hangers 93 125 153 65 Figure 7 Mounting drill dimensioning all dimensions in mm ...