AN680XX emulation mode
1GP71_0E
51
Rohde & Schwarz
Status
Command / Function / Remark / Limitation
[:SOURce:]SWEep<n>:TIME value
Set / Query the sweep time.
Value:
timemin … timemax [S | MS | US | NS] | MIN | MAX
Default:
TBD for frequency sweep.
TBD for power sweep
Remark:
value
is splitted into DWELl and POINts, whereby DWELl is set to minimal possible
value so that POINTs does not exceed upper limit.
SWEep[1] is used for frequency sweep, SWEep2 is used for power sweep.
[:SOURce:]SWEep<n>:TIME:AUTO value
[:SOURce:]SWEep<n>:TIME:LLIMit value
Table 43: SOURCE subsystem
•
STATus Subsystem
Status
Command / Function / Remark / Limitation
STATus:OPERation[:EVENt]?
Query the event bits of the operation status register.
STATus:OPERation:CONDition?
Query the condition bits of the operation status register.
STATus:OPERation:ENABle value
Set / Query the enable bits of the operation status register.
Value:
0 … 32757
Default:
0
STATus:OPERation:NTRansition value
Set / Query the negative transition filter bits of the operation status register.
Value:
0 … 32757
Default:
0
STATus:OPERation:PTRansition value
Set / Query the positive transition filter bits of the operation status register.
Value:
0 … 32757
Default:
32757
STATus:PRESet
Preset the operation and questionable register contents.