Section VII – Maintenance
Quincy Vacuum Pump-QSV Series 91
8. Remove the oil filters.
• Clean the seat on the manifold.
• Lubricate the gasket of the new oil filters and screw them into place.
• Tighten the gasket firmly by hand.
9. Disconnect the oil injection hose (1) and drain the oil.
• Check the condition of the O-ring before re-assembly, replace if necessary.
10. Drain the oil from water cooler if a water cooler is installed.
11. The oil collected in an oil waste can, deliver it to the local collection service.
12. Refit the vent plug after draining.