Section VIII – Problem solving
Quincy Vacuum Pump-QSV Series 99
(1)
Main motor convertor alarm
(2)
Fault
Convertor
If a problem is detected by the converter, a specific code (Main motor converter alarm) will appear on the
graphic regulator display, together with a fault code and a fault description.
Typical display, Main Motor Converter Alarm (1), Fault (2) Code (0x7130) and description (Motor over
temperature (3)) in this case.
Below table lists the most important error codes. If another code appears, please contact Quincy.
Fault code
Fault
Remedy
2
(or 60000)
DC Bus Undervoltage (Uv1)
Check supply voltage
Check input wiring
Check EMC filter
3
(or 60000)
Control Power Supply Voltage Fault (Uv2)
Check supply voltage
Check input wiring
Check EMC filter
4
(or 60000)
Undervoltage 3 (Uv3)
Check supply voltage
Check input wiring
Check EMC filter
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...