Section VII – Maintenance
Quincy Vacuum Pump-QSV Series 85
Preventive maintenance schedule
Daily and 3-monthly check list for normal applications
Period
Operation
Daily
Check oil level and condition. (see section Operations instructions / During operation)
Check readings on display.
Drain outlet collector.
Monthly (1)
Remove the air filter elements and inspect. Replace damaged or heavily contaminated
elements. Check for possible air and oil leakages.
3-monthly (1)
Check coolers, clean if necessary.
Check the filter elements of the electric cabinet. Replace if necessary
Check the silencer of the blow off valve, clean if necessary.
(1) Depending on type of application (normal, medium, harsh) this needs to be done more frequently.Consult
your Quincy Customer Center.
Preventive Maintenance schedule programmed in the Airlogic for normal applications
Type of application
Action
Normal
Medium
Harsh
Check oil level and condition
Daily
Daily
Daily
Check readings on display
Drain outlet collector
Remove the air filter elements and inspect
Replace damaged or heavily contaminated elements
Monthly
Monthly
Weekly
Check for possible air and oil leakages
Check coolers, clean if necessary
3-Monthly
3-Monthly
Monthly
Check the filter elements of the electric cabinet.
Replace if necessary
Check the silencer of the blow off valve, clean if
necessary
Change oil *
4000 hrs (1) (4)
2000 hrs (1) (4)
1000 hrs (1) (4)
Change oil filters
Replace the air filters element
Replace the oil separator elements
4000 hrs (1)
4000 hrs (1)
2000 hrs (1)
Check pressure and temperature readings
Check operation of cooling fans of converter and
clean heatsink
Check blow off solenoid valve
Clean coolers
Check and clean cooling fan assembly
Regreasing of motor bearings
Check electronic thermostatic valve
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...