Section III - Airlogic Graphic controller
Quincy Vacuum Pump-QSV Series 59
Move the cursor to the Password icon (see above, section Menu icon).
Select Modify using the Scroll keys and press the Enter key. Next, modify the password as required.
3.17 Programmable settings
Vacuum pump/motor
Minimum
setting
Factory setting Maximum setting
Pressure band high 1
mbar (a)
201
300
1000
psi
2.91
4.35
14.50
Pressure band low 1
mbar (a)
150
200
1000
psi
2.17
2.9
14.50
Pressure band high 2
mbar (a)
301
400
1000
psi
4.36
5.80
14.50
Pressure band low 2
mbar (a)
150
300
1000
psi
2.17
4.35
14.50
Proportional band
%
5
10
15
Integration time
sec
0,5
5
10
Run at minimum pressure
sec
0
30
300
Min stop time
sec
5
5
30
Power recovery time
sec
10
10
3600
Restart delay
sec
0
0
1200
Communication time-out
sec
10
30
60
Fan motor start per day
1
240
240
Service plan
The built-in service timers will give a Service warning message after their respective pre-programmed time interval
has elapsed.
For specific data, see section Preventive Maintenance.
Consult Supplier if a timer setting needs to be changed. The intervals must not exceed the nominal intervals and
must coincide logically. See section Modifying general settings.
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...