Section III - Airlogic Graphic controller
Quincy Vacuum Pump-QSV Series 39
(i)
Service
(ii)
Overview
(iii)
Service plan
(iv)
Next service
(v)
History
Scroll through the items to select the desired item and press the Enter key to see the details as explained
below.
Overview
(i)
Overview
(ii)
Running hours
(iii)
Real time hours
(iv)
Reset
Example for service level (A):
The figures at the left are the programmed service intervals. For Service interval A, the programmed number of
running hours is 4000 hours (upper row) and the programmed number of real time hours is 8760 hours, which
corresponds to one year (second row).
This means that the controller will launch a service warning when either 4000 running hours or 8760 real hours are
reached, whichever comes first. Note that the real time hours counter keeps counting, also when the controller is
not powered.
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...