Section IX – Technical data
Quincy Vacuum Pump-QSV Series 107
9.2 Electrical cable size
Important
NOTICE!
The voltage on the vacuum pump terminals must not deviate more than 10% of the nominal voltage.
It is however highly recommended to keep the voltage drop over the supply cables at nominal current
below 5% of the nominal voltage (IEC 60204-1).
•
If cables are grouped together with other power cables, it may be necessary to use cables of a
larger size than those calculated for the standard operating conditions.
•
Use the original cable entry. See section Dimension drawings.
To preserve the IP protection degree of the electric cubicle and to protect its components from
dust from the environment, it is mandatory to use a proper cable gland when connecting the
supply cable to the Vacuum pump.
•
Local regulations remain applicable if they are stricter than the values proposed below.
Caution:
•
Always double-check the fuse size versus the calculated cable size. If required, reduce fuse
size or enlarge cable size.
Cable length should not exceed the maximum length according to IEC60204 table 10
Leakage breaker (optional)
If the installation requires a leakage breaker, always use an all current sensitive leakage breaker, RCM or
RCD Type B (according to IEC/EN 60755) with a sufficient trip level.
Currents and fuses
IEC and UL/cUL approval
Vacuum pump specification
Itot
Imax undervoltage
Primary
Secondary
Primary Secondary
Pump
Voltage
Frequency
Approval
I tot
I tot
I tot
I tot
V
Hz
A
A
A
A
QSV 2200
380
60
IEC
112.0
-
124.4
-
QSV 2200
460
60
IEC/CSA/UL
93.2
-
103.6
-
QSV 2200
400
50
IEC
106.6
-
118.4
-
QSV 2200
200
50
IEC
219.8
106.6
244.2
118.4
QSV 2200
230
60
CSA/UL
192.2
93.2
213.6
103.6
QSV 2200
500
50
IEC
87.9
106.6
97.7
118.4
QSV 2200
575
60
CSA/UL
76.9
93.2
85.4
103.6
QSV 2700
380
60
IEC
150.7
-
167.4
-
QSV 2700
460
60
IEC/CSA/UL
125.2
-
139.1
-
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...