Section VIII – Maintenance
86 Quincy Vacuum Pump-QSV Series
Type of application
Action
Normal
Medium
Harsh
Check scavenge line
4000 hrs (1)
4000 hrs (1)
2000 hrs (1)
Replace the filter element of electric cabinet
8000 hrs (2)
6000 hrs (2)
4000 hrs (2)
Test pressure switch
Motor overhaul
24000 hrs
24000 hrs
24000 hrs
Change lipseal assembly
24000 hrs
24000 hrs
24000 hrs
Element overhaul
48000 hrs
36000 hrs
24000 hrs
Replace piston of electronic thermostatic valve
24000 hrs
24000 hrs
24000 hrs
(1)
or yearly, whichever comes first
(2)
or every 2 years, whichever comes first
(3)
When using sythentic oil the indicated number of running hours can be doubled
* In medium and harsh applications an optional 500 hrs oil sample is recommended.
HWHcap option always use sythentic oil and harsh service intervals
The indicated service exchange intervals are valid for standard operating conditions (see section Reference
conditions and limitations) and nominal operating pressure (see section Vacuum pump data). Exposure of
the vacuum pump to external pollutants, operation at high humidity combined with low duty cycles or
operation at higher temperatures may require a shorter service exchange interval. Contact Quincy if in doubt.
NOTICE!
Vacuum pumps with optional high water handling capability (humid version) are recommended for use with
Quincy vacuum Synthetic fluid only.
Quincy vacuum Mineral fluid
Ambient temperature
Element outlet
temperature
Exchange interval *
Maximum time interval *
up to 25 °C
up to 90 °C
4000 hours
1 year
from 25 °C up to 35 °C
from 90 °C up to 100 °C
3000 hours
1 year
more than 35 °C
more than 100 °C
2000 hours
1 year
Quincy vacuum Synthetic fluid
Ambient temperature
Element outlet
temperature
Exchange interval *
Maximum time interval *
up to 40 °C
up to 110 °C
8000 hours
2 year
more than 40°C
more than 110 °C
6000 hours
2 year
Содержание QSV 2200
Страница 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Страница 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Страница 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Страница 119: ...Section XII Declaration of conformity Quincy Vacuum Pump QSV Series 119 Declaration of conformity...
Страница 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Страница 123: ......
Страница 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...