background image

Section I - General

 

Quincy Compressor-QSI

®

 

3

Safety Precautions

Read this manual and follow all instructions prior to 

installing or operating this compressor.

Listed below are some, but not all, safety precautions that 

must be observed with compressors and compressed air 

systems.

WARNING!

Failure to follow any of these precautions may 

result in severe personal injury, death, property 

damage and/or compressor damage.

•  Air from this compressor will cause severe injury or 

death if used for breathing or food processing.  Air 

used for these processes must meet OSHA 29 CFR 

1910.134 regulations.

•  Disconnect and lockout all power supplies to the 

compressor plus any remote controllers prior to ser-

vicing the unit.

•  Never assume it is safe to work on the compressor 

because it is not operating.  Many installations have 

automatic start/stop controls and the compressor may 

start at any time.

•  This compressor is designed for use in the compres-

sion of normal atmospheric air only.  No other gases, 

vapors or fumes should be exposed to the compressor 

intake, nor processed through the compressor.

•  Relieve all pressure internal to the compressor prior 

to servicing.  Do not depend on check valves to hold 

system pressure.

•  A properly sized pressure relief valve must be 

installed in the discharge piping ahead (upstream) of 

any shut-off valve (block valve), heat exchanger, ori

-

fice or any potential blockage point.  Failure to install 

a pressure relief valve could result in the rupturing or 

explosion of some compressor component.

•  Do not change the pressure setting of the pressure 

relief valve, restrict the function of the pressure relief 

valve, or replace the pressure relief valve with a plug.  

Over pressurization of system or compressor compo-

nents can occur, resulting in death, severe personal 

injury or property damage.

•  Never use plastic pipe, rubber hose, or soldered 

joints in any part of the compressed air system.  Fail

-

ure to ensure system compatibility with compressor 

piping is dangerous.

•  Never use a flammable or toxic solvent for cleaning 

the air filter or any parts.

•  Do not remove any guards or cabinet panels or 

attempt to service any compressor part while the 

compressor is operating.

•  Do not operate the compressor at pressures in excess 

of its rating.

•  Observe control panel displays daily to ensure com-

pressor is operating properly.

•  Follow all maintenance procedures and check all 

safety devices on schedule.

•  Never disconnect or tamper with the high air tem-

perature (HAT) sensors.

•  Compressed air is dangerous, do not play with it.

•  Use the correct fluid at all times.

•  Do not rely on the discharge air line check valve.

•  Do not override any safety or shutdown devices.

•  Keep doors closed during operation.  The noise level 

inside cabinet exceeds 100 decibels (dBA) and the 

operating temperature of some components is suf-

ficient to burn the skin.

 NOTICE!

These instructions, precautions and descriptions 

cover standard Quincy manufactured QSI

®

 Series 

air compressors.  As a service to our customers, 

we often modify or construct packages to the 

customers specifications.  This manual may not 

be appropriate in those cases.

 NOTICE!

Every effort has been taken to ensure complete 

and correct instructions have been included in this 

Содержание QSI Series

Страница 1: ...ON GO TO WWW P65WARNINGS CA GOV QSI Series Fixed Speed Rotary Screw Air Compressors Instruction Manual This manual contains important safety information and should be made available to all personnel w...

Страница 2: ......

Страница 3: ...SI Rotary Screw Air Compressors Seller s sole obligation on this warranty shall be at its option to repair replace or refund the purchase price of any product or part thereof which proves to be defect...

Страница 4: ...IMPORTANT Throughout this manual we have identified key hazards The following symbols identify the level of hazard seriousness DANGER This symbol identifies immediate hazards which will result in seve...

Страница 5: ...ponent Do not change the pressure setting of the pressure relief valve restrict the function of the pressure relief valve or replace the pressure relief valve with a plug Over pressurization of system...

Страница 6: ...ch Quincy Compressor Division maintains replacement parts for Quincy compressors A repair parts list is shipped with all new machines Order parts from your Authorized Quincy distributor Use only genui...

Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...

Страница 8: ...tical cabinets are available to reduce sound levels Figure 2 1 Compression Cycle A INTAKE B COMPRESSION C DISCHARGE INLET PORT CYLINDER MALE ROTOR FEMALE ROTOR DISCHARGE PORT The Compression Cycle The...

Страница 9: ...erature at the compressor of approximately 180 F Water cooled Fluid Coolers Water cooled fluid coolers are of the shell and tube de sign Fluid passes through the shell transferring its heat to the wat...

Страница 10: ...ve is held in a closed position preventing the intake of air into the compressor and serving as a check valve preventing reverse air fluid flow through the inlet valve and air filter Auto Dual Standar...

Страница 11: ...chine If the demand is greater than one unit s capability the second com pressor will automatically turn itself on until the excess demand has been satisfied Again working with the stan dard Auto Dual...

Страница 12: ...r is provided with a NEMA 1 enclosure Optional panels include NEMA 4 Air cooled models utilize a second magnetic starter for protection of the fluid cooler fan motor This starter is connected to the c...

Страница 13: ...Differential Light This indicates excessive pressure differential across the air fluid separator element It is used to determine separa tor element change intervals Air Intake Filter Service Light Th...

Страница 14: ...mage should be reported to the delivering carrier within 15 days of delivery The delivering carrier must prepare a damage report Item ized supporting papers are essential to filing a claim Read the co...

Страница 15: ...Control the compres sor temperatures and monitor compressor fluid for signs of water contamination Fluid and filter changes may need to be increased in high humidity areas Increased operating temperat...

Страница 16: ...uring installation a suitable fused disconnect switch or circuit breaker should be provided Any unreasonable voltage unbalance 5 between the legs must be eliminated and any low voltage corrected to pr...

Страница 17: ...e water inlet and discharge connections are correct NOTICE The water temperature regulating valve is located in the discharge water line Clean air is essential for your Quincy QSI compressor Always se...

Страница 18: ...equire ments have been met and that the purpose and use of the controls are thoroughly understood Before placing the compressor into operation do the following Remove all loose items and tools from ar...

Страница 19: ...ction VI Servicing Never increase air pressure settings beyond factory specifications Observe compressor operation closely for the first hour of operation and frequently for the next seven hours Stop...

Страница 20: ...n LED Indicates that the regulator is automatically controlling the compressor 8 Voltage on LED Indicates that the voltage is switched on 9 Pictograph Voltage on 10 Enter key Key to select the paramet...

Страница 21: ...running the icon is rotates Compressor status Motor stopped Running unloaded Running loaded Machine control mode Local control Remote start stop Network control Automatic restart after voltage failur...

Страница 22: ...een Chart low medium and high resolution available and will show pressure vs time ECO shows the present state of all the six compressor slots Input icons Icon Description Pressure temperature Digital...

Страница 23: ...r QSI 21 Failure expansion module Network problem General alarm Input icons Icon Description Inputs Outputs Alarms Warnings shutdowns Counters Test Settings Service Event history saved data Access key...

Страница 24: ...eys 2 Enter key 3 Back key Function The Main screen shows the status of the compressor operation and is the gateway to all functions implemented in the controller The Main screen is shown automaticall...

Страница 25: ...23 Typical Main screen fixed speed compressors running loaded Text on figures Number Fixed Speed 1 Compressor Outlet Package Pressure 2 Element Outlet Temperature 3 Running Hours 4 Load text varies u...

Страница 26: ...op up icons These icons pop up if a machine failure occurs warnings shutdowns service To call up more information about the icons shown select the icon using the scroll keys and press the enter key Se...

Страница 27: ...ection Main screen To go to the Menu screen highlight the Menu button 5 using the Scroll keys Press the Enter key to select the menu Following screen appears The screen shows a number of icons Each ic...

Страница 28: ...roll keys 2 Enter key 3 Back key Menu icon Inputs Function To call up information regarding the actually measured data and the status of some inputs such as the emergency stop switch Procedure Startin...

Страница 29: ...ys move the cursor to the Inputs icon see above section Menu icon Press the Enter key A screen similar to the one appears below Text on figures 1 Inputs 2 Compressor outlet 3 Element outlet 4 Emergenc...

Страница 30: ...on and the Warning icon in the screen shown above Outputs menu Control panel 1 Scroll keys 2 Enter key 3 Back key Menu icon Outputs Function To call up information regarding the actual status of some...

Страница 31: ...incy Compressor QSI 29 Text on figures 1 Menu 2 Regulation Move the cursor to the Outputs icon see above section Menu icon using the Scroll keys Press the Enter key A screen similar to the one appears...

Страница 32: ...noid Valve HGBP 1 10 Solenoid Valve HGBP 2 11 Solenoid Valve HGBP 3 12 Solenoid Valve HGBP 4 13 Release Valve The screen shows a list of all outputs with their corresponding icons and readings If an i...

Страница 33: ...that the regulator has been powered The number of load cycles Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Following scree...

Страница 34: ...ssor QSI 1 Counters 2 Running hours 3 Loaded hours 4 Motor starts 5 Load relay 6 Module hours The screen shows a list of all counters with their actual readings Service menu Control panel 1 Scroll key...

Страница 35: ...vals Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Following screen appears Using the Scroll keys move the cursor to the Ser...

Страница 36: ...hours counter keeps counting also when the controller is not powered The figures within the bars are the number of hours to go till the next service intervention In the example above the compressor ha...

Страница 37: ...nning hours 4 Real time 5 Modify Modifying a service plan Dependant on the operating conditions it might be necessary to modify the service intervals To do so use the Scroll keys to select the value t...

Страница 38: ...xample above the A Service level is programmed at 4000 running hours of which 1 hours have passed History The History screen shows a list of all service actions done in the past sorted by date The dat...

Страница 39: ...is menu is also used to select the active pressure band Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Following screen appea...

Страница 40: ...fy the settings move the cursor to the action button Modify and press the Enter key Following screen appears The first line of the screen is highlighted in gray Use the Scroll keys to highlight the se...

Страница 41: ...ove the cursor to the action button Menu and press the Enter key Then using scroll keys move the cursor over Event History and then press Enter key Following screen appears Using the Scroll keys move...

Страница 42: ...l panel 1 Scroll keys 2 Enter key 3 Back key Menu icon Settings Function To display and modify a number of general settings e g Time Date Date format Language units and also the optional settings e g...

Страница 43: ...res Quincy Compressor QSI 41 Using the Scroll keys move the cursor to the Settings icon see above section menu icon Press the Enter key Move your cursor to General and press Enter key The screen below...

Страница 44: ...is covering the first item Language Use the key of the Scroll keys to select the setting to be modified and press the Enter key A pop up screen appears Use the or key to select the required parameter...

Страница 45: ...access to different end user levels can be defined using the designated numbers for those user levels Procedure Starting from the main screen See Main Screen Move the cursor to the action button Menu...

Страница 46: ...on button Menu and press the Enter key In the Menu screen move the cursor to set tings and press Enter key again Following screen appears Using the scroll keys move the cursor to the Network icon see...

Страница 47: ...n IV Operating Procedures Quincy Compressor QSI 45 key Using scroll keys the submenus can be modified Again go back to the Network screen and select Ethernet Press Enter key and following screen will...

Страница 48: ...of time Also a delay can be set up to 2 minutes to start the unit after the power is back Procedure Starting from the main screen See Main Screen Move the cursor to the action button Menu and press th...

Страница 49: ...oint any value can be set according to the user needs Procedure Starting from the main screen See Main Screen Move the cursor to the action button Menu and press the Enter Key In the Menu screen move...

Страница 50: ...Section IV Operating Procedures 48 Quincy Compressor QSI Info menu Control panel 1 3 2 1 Scroll keys 2 Enter key 3 Back key...

Страница 51: ...configuration of the controller Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Following screen appears Using the Scroll key...

Страница 52: ...er commands for the net pressure band Four different week schemes can be programmed A week cycle can be programmed a week cycle is a sequence of 10 weeks For each week in the cycle one of the four pro...

Страница 53: ...the Enter key on the controller to modify Programming week schemes Select Week action schemes and press Enter A new window opens The first item in the list is highlighted in red Press the Enter key o...

Страница 54: ...hursday 6 Friday 7 Saturday 8 Sunday A new window opens The Modify action button is selected Press the enter button on the controller to create an action 1 Monday 2 Modify A new pop up window opens Se...

Страница 55: ...2 Actions 3 Remove 4 Start 5 Stop 6 Pressure Setpoint 1 7 Modify A new window opens The action is now visible in the first day of the week 1 Monday 2 Start 3 Save 4 Modify To adjust the time use the...

Страница 56: ...key of Scroll keys to modify the values of the hours Use the or Scroll keys to modify the minutes After selecting the time press Enter key and the new time should be shown 1 Monday 2 Time 3 Save 4 Mod...

Страница 57: ...4 Modify A new pop up window opens Use the Scroll keys on the controller to select the correct actions Press the Enter key to confirm 1 Monday 3 Are you sure 4 No 5 Yes 6 Save 7 Modify Press the Back...

Страница 58: ...key on the controller to leave this screen Programming the week cycle A week cycle is a sequence of 10 weeks For each week in the cycle one of the four programmed week schemes can be chosen Select We...

Страница 59: ...Week 3 5 Week 4 6 Modify Press twice the Enter key on the controller to modify the first week A new window opens Select the action example Week Action Scheme 1 1 Week Cycle 2 Week 1 3 Off 4 Week Acti...

Страница 60: ...menu Select the status of the Week Timer 1 Week Timer 2 Week Action Schemes 3 Week Cycle 4 Status 5 Week Timer Inactive 6 Remaining Running Time A new window opens Select Week 1 to set the Week Timer...

Страница 61: ...e Week Timer menu Select Remaining Running Time from the list and press the Enter key on the controller to Modify 1 Week Timer 2 Week Action Schemes 3 Week Cycle 4 Status 5 Remaining Running Time This...

Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...

Страница 63: ...ne in steps of 12 5 maximum and can go upto 50 i e 4 steps Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key In the Menu screen...

Страница 64: ...ress the Enter key Settings can be changed using up down scroll keys Menu Icon ECOi Function To determine the master slave configuration for controllers running in a network mode and also defines how...

Страница 65: ...ars Using the scroll keys move the cursor to the Modify option and press Enter key Now the ECO option should be highlighted Gray represents current selection Press enter key again A new window will op...

Страница 66: ...Using scroll keys select regulation press the Enter key and six options would be seen two different pressure bands in use pressure band and digital pressure band selec tion on the regulation screen T...

Страница 67: ...Section IV Operating Procedures Quincy Compressor QSI 65 The next item is General Using scroll keys select general and press the Enter key Following window ap pears...

Страница 68: ...ssors will follow the master settings For Remote control it s similar to LAN control but to activate Remote start stop we need to run the compressors at Remote control Remote start stop under General...

Страница 69: ...ommands Using scroll keys select commands and press the Enter key Following window appears Here two options are available Central Stop and Local If command central stop is on then all the compres sors...

Страница 70: ...xt item is Automatic Restart This option restarts the compressor at its previous state if the power down time is less than the maximum power down time To get it activated use scroll keys to select aut...

Страница 71: ...e final option available here is Compressors It has four more sub options and they are all based on how the slave compressors would react to master settings To select this use scroll keys to select co...

Страница 72: ...mpressors that have the same priority the available compressor with the least running hours will be started first compressors with the most running hours will be stopped first However this is not appl...

Страница 73: ...during a long time Next is Counters This option shows the running hours for different compressors in the same network Also it is possible to edit these running hours if necessary and that would incre...

Страница 74: ...Quincy Compressor QSI Third option is Timers This has some specific timing based programs and they can be changed as desired To use this first using scroll keys move cursor to counters and then press...

Страница 75: ...load requests 3 Unload Load Time Time between two unload load requests 4 Manual seq Shift Up Delay The delay due to increase in pressure to start loading the next compressor 5 Manual seq Shift Down De...

Страница 76: ...s Here the group sequences are created for the manual sequence mode As only six compressors can be connected at one particular network so six groups can be defined at a maximum To use this first using...

Страница 77: ...ve compressor no there are four menus First one is Priority Under priority there are two schemes In each Priority scheme a Priority Level can be set per compressor The lower the priority level the hig...

Страница 78: ...Quincy Compressor QSI Second menu item under compressor no is General Here separating the slave from master setting selecting sequence group and flow can be changed Using scroll keys and selecting mo...

Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...

Страница 80: ...Section IV Operating Procedures 78 Quincy Compressor QSI Next item is Timers Using scroll keys move cursor to timers and press Enter key Following screen will appear...

Страница 81: ...ad Reaction Time Maximum time for the compressor to reply to a Load command 3 Unload Reaction Time Maximum Time for the compressor to reply to an Unload command 4 Stop Reaction Time Maximum Time for t...

Страница 82: ...sor will be seen as a Fixed Speed compressor running at optimal maximum speed Since these VSD s are seen as fixed speed compressors a Number of starts per day is required for the regulation 2 VSD Maxi...

Страница 83: ...plant air system to prevent any back up of air flow into the area to be serviced NEVER depend upon a check valve to isolate the system 3 Open the manual vent valve and wait for the pres sure in the sy...

Страница 84: ...Verify the power wire and ground connections at the compressor starter are tight and in good order Also verify the wire connections from the compressor starter to the compressor motor are tight and i...

Страница 85: ...oved The frequency with which water must be re moved is determined by the ambient air conditions Dur ing hot and humid conditions water should be drained off the bottom of the reservoir daily In cold...

Страница 86: ...ct the grounding staple on the separator ele ment gasket with the ground probe of the test indica tor 4 Touch the top cap of the separator element with the other probe The indicator light should illum...

Страница 87: ...a two stage dry type element The first stage is cyclonic That is centrifugal airflow spins the larger dirt particles to the outside walls of the filter canister In the second stage air passes through...

Страница 88: ...ck valve is stuck closed the seal cavity will not scavenge Replace if neces sary Remove the coupling guards and coupling halves Remove the drive coupling hub and key from the compressor shaft Remove t...

Страница 89: ...ation Apply a thin coat of compressor fluid to the outer face of the wear sleeve and seal lip Slide the proper seal installation sleeve against the wear sleeve with the taper toward the end of the rot...

Страница 90: ...HE GROOVE POSITION AND HOLD FLAT SEALING FACE AGAINST O RING 2 BACK OFF NUT BACK OFF LOCKNUT TO ITS UPPERMOST POSITION 3 THREAD INTO PORT THREAD FITTING INTO THE PORT UNTIL THE BACKUP WASHER CON TACTS...

Страница 91: ...compressed air discharge tempera ture to seal the rotor clearances Fluid Specifications We recommend that all Quincy rotary screw compressors be filled with one of the following synthetic fluids Quin...

Страница 92: ...design life of the com pressor or cause problems with filtration or carryover Consult the Quincy Service Department before changing brands of fluid Fluid Level Fluid level is monitored by a sightglas...

Страница 93: ...dge and replac ing it with a new one NOTICE Use genuine Quincy replacement filters only Figure 1 3 Spin on Fluid Filter The initial filter change should occur after the first 500 hours of operation Du...

Страница 94: ...mpressors operating on QuinSyn flu ids Monitoring of the total acid number TAN barium level and or viscosity throughout the life of the fluid pro vides maximum protection to your machine while best ut...

Страница 95: ...rain water from the reservoir Disposal QuinSyn PG is considered nonhazardous waste Disposal of this fluid should be done in accordance with Local State and Federal regulations Separation of this fluid...

Страница 96: ...rt 566 Typical Properties of QuinSyn XP ISO 68 Viscosity 100 F ASTM D445 60 0 cSt Viscosity 210 F ASTM D445 9 8 cSt Viscosity Index ASTM D2270 131 Specific Gravity 60 60 0 95 Flash Point ASTM D92 570...

Страница 97: ...tability Excellent oxidative stability Better gas fluid separation Typical Properties of QuinSyn Plus ISO 46 Viscosity 100 F ASTM D445 46 0 cSt Viscosity 210 F ASTM D445 7 5 cSt Viscosity Index ASTM D...

Страница 98: ...warranties are not available with the use of QuinSyn IV QuinSyn QuinSyn is a Polyalphaolefin PAO type synthetic fluid Effective November 1 2000 QuinSyn Compressor Fluid is no longer available as a fac...

Страница 99: ...mineral oils and QuinSyn synthetic fluids and is highly recommended for use as a flushing fluid when converting to QuinSyn PG from QuinSyn or QuinSyn IV Applications Cleaning fluid for removal of var...

Страница 100: ...the follow ing procedure Drain thoroughly as in A and fill with QuinSyn Flush Run the machine for 300 hours and take a fluid sample Send fluid sample to Quincy Compressor Fluid Analy sis to determine...

Страница 101: ...ompressor Fluid Analysis to determine if further flushing is needed Continue operating com pressor until the results of fluid analysis are known Drain or continue to run compressor as advised by the f...

Страница 102: ...eral oils or PAO fluids flush the compressor with QuinSyn Flush following the procedures outlined on page 35 Converting to QuinSyn Plus Normal Machines A Any QuinSyn fluid except QuinSyn PG No flush r...

Страница 103: ...must be placed on drain ing after each step Contaminants left in the compressor after flushing have a direct effect on the fluid s life Once the oxidized material varnish is dissolved in the Quin Syn...

Страница 104: ...anner 2 Fill sample bottle 3 Close valve After collecting sample from either of the above methods 1 Fill out information label completely Be certain to provide all information as to possible hazards r...

Страница 105: ...n Sample Values below are in parts per million ppm Date Silver Alum Chrom Copp Iron Nickel Lead Tin Titan Vanad Bari Calc Mag Mol Sod Phos Sili Zinc Fluid Hours Ag Al Cr Cu Fe Ni Pb Sn Ti V Ba Ca Mg...

Страница 106: ...EL NUMBER The model number of the Quincy compressor that the fluid sample was taken from i HOURS ON FLUID These are the actual hours that the QuinSyn fluid has been in the unit since the last fluid ch...

Страница 107: ...on QuinSyn PG 0 40 50 100 QuinSyn XP 0 40 50 100 QuinSyn Plus 0 5 20 20 Phosphorus PPM Plasma Emission QuinSyn PG 0 5 20 20 QuinSynXP 50 5 20 0 QuinSyn Plus 0 5 20 20 Zinc PPM Plasma Emission All 0 10...

Страница 108: ...20 20 Phosphorus PPM Plasma Emission All 0 5 20 20 Zinc PPM Plasma Emission All 0 100 200 200 WEAR METALS Silver PPM Plasma Emission All 0 5 10 10 Aluminum PPM Plasma Emission All 0 5 10 10 Chromium...

Страница 109: ...ck wise To lower the pressure turn the screw out counter clockwise Maximum full load pressure is 110 PSIG for standard QSI units Minimum full load pressure with modulation and standard controls is 75...

Страница 110: ...cked again The QSI series compressors utilize a two piece flexible element bolted to steel hubs on the com pressor motor shafts The following steps will ensure a properly aligned coupling 1 Tag and lo...

Страница 111: ...l be referred to as B 5 Divide measurement A by measurement B 6 Multiply the result from step 5 by the indicator reading C to determine the amount of shim to be placed under either the front feet or t...

Страница 112: ...the compressor coupling half so that it reads from the outside surface of the motor coupling half 2 Position the indicator on the side of the coupling 3 Rotate the coupling halves together 180 in the...

Страница 113: ...art the compressor Correct the cause of the motor overloaded condition reset the overload relay and press the reset button Check power supply and transformer fuses Contact a qualified service technici...

Страница 114: ...accordance with the instruction in the High Discharge Air Temperature sectionofthistroubleshooting guide Restart the compressor Correct the cause of the overloaded condi tion reset overload relay and...

Страница 115: ...t in and cut out pressure Ensure unload pressure does not exceed maximum operating pressure Correct in accordance with instruction on Inlet Valve not opening or closing in rela tion to air demand sect...

Страница 116: ...ce lines for leaks with soap suds Repair as necessary Correct in accordance with the instructions in Inlet valve not opening or closing in rela tion to air demand section of troubleshoot ing guide Rep...

Страница 117: ...es of fluid Do not mix fluids from different manufactur ers Follow fluid specifications as described in Compressor Fluids section of this manual Change fluid Service air filter and fluid filter in acc...

Страница 118: ...filter elements replace them If air filter is inadequate for the environment relocate the intake air to a clean source Replace fluid filter element Correct in accordance with the instruction in Fluid...

Страница 119: ...er Clogging Compressor operating in highly contaminated atmosphere Air cleaner not adequate for conditions Check air inlet valve bushing and shaft Check piston and cylinder bore Repair or replace as n...

Страница 120: ...ential pilot valve Leaks in control lines Leaks in service lines Adjustfluidleveltorecommendedfluidlevel by draining the reservoir Use fluid level gauge as a guide Clean scavenger line orifice and tub...

Страница 121: ...ogged moisture separator trap Installation Application Faulty cooler leaks Adjust differential pressure regulator to obtain desired modulation range Readjust air pressure switch so that the com presso...

Страница 122: ...ty pressure relief valve Excessive Water Content In Fluid Water drain intervals 4Discharge temperature too low Check and tighten wiring terminals Check and repair air inlet valve Repair or replace as...

Страница 123: ...water from air fluid reservoir Service air filter as needed daily or weekly if extremely dirty conditions exist Cleanaftercoolerandfluidcoolerfins air cooled only Wipeentireunitdowntomaintainappearan...

Страница 124: ...ction Fluid Cooler BTU min 1893 1994 2124 2387 Aftercooler BTU min 352 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 2 Fan Motor rpm 1...

Страница 125: ...420 2618 2932 Aftercooler BTU min 449 450 453 454 Aftercooler Approach standard conditions F 6 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 2 Fan Motor rpm 1790 Fan Flow cfm 4500 W...

Страница 126: ...Fluid Cooler BTU min 2808 2957 3184 3581 Aftercooler BTU min 522 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 3 Fan Motor rpm 1750 F...

Страница 127: ...ction Fluid Cooler BTU min 3768 3966 4255 4785 Aftercooler BTU min 792 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 5 Fan Motor rpm 1...

Страница 128: ...4911 5292 5972 Aftercooler BTU min 1016 1018 1017 1025 Aftercooler Approach standard conditions F 6 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 5 Fan Motor rpm 1790 Fan Flow cfm...

Страница 129: ...luid Cooler BTU min 5755 6058 6512 7327 Aftercooler BTU min 1187 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 5 Fan Motor rpm 1165 Fa...

Страница 130: ...r BTU min 7609 7730 8310 Aftercooler BTU min 1530 1610 1731 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 5 Fan Motor rpm 1180 Fan Flo...

Страница 131: ...BTU min 9592 10096 10853 Aftercooler BTU min 1913 2014 2165 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 10 Fan Motor rpm 1170 Fan F...

Страница 132: ...oler BTU min 11611 12223 13125 Aftercooler BTU min 2296 2417 2677 Aftercooler Approach standard conditions F 3 5 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Motor HP 10 Fan Motor rpm 1170...

Страница 133: ...cooling water is from other than a municipal water supply Dirt and debris can plug the water passages very quickly rendering the cooler ineffective Write the factory for water strainer recommendation...

Страница 134: ...in the water chambers of the exchanger to protect it from damage by freezing temperatures Drains are provided in most standard models The oil chamber of the exchanger may become filled with sludge acc...

Страница 135: ..._________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____...

Страница 136: ..._________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____...

Страница 137: ...11 Section III Installation Receiving 12 Moving the Unit to the Installation Site 12 Location 13 Piping Connections 13 Relief Valves 14 Electrical 14 Guards 14 Manual Vent and Shutoff Valves 15 Water...

Страница 138: ...Fittings 88 Section VII Compressor Fluids Fluid Specifications 89 Lubrication 90 Fluid Level 90 Fluid Sample Valve 91 Fluid Filter 91 Factors Affecting Fluid Life 92 Fluid Analysis Program General 92...

Страница 139: ...d Units Only 107 Drive Coupling Alignment 108 110 Section IX Troubleshooting Troubleshooting 111 121 Section X Maintenance Schedule Maintenance Schedule 121 Appendix A Technical Data Technical Data 12...

Страница 140: ...Table of Contents Quincy Compressor QSI...

Страница 141: ...er pipe has been used for the compressor package being installed Undersized pipe or poor routing of pipe will degrade the performance of the compressor package Inspect all connections to insure they a...

Страница 142: ...2018 Quincy Compressor All Rights Reserved Litho in U S A Quincy Compressor Products 251 937 5900 E mail info quincycompressor com Website www quincycompressor com...

Отзывы: