Appendix A - Technical Data
Quincy Compressor-QSI
®
123
QSI 300
Standard
Full Load Operating Pressure
psig
100
110
125
150
Maximum Operating Pressure
psig
115
125
140
165
Minimum Operating Pressure
psig
75
Maximum Ambient Operating Temperature:
Less Cabinet
°F
118
With Cabinet
°F
110
Minimum Ambient Operating Temperature
°F
35
Compressor Drive Motor
HP
60 75
Rotor Diameter
mm
204
Male Rotor Speed
rpm
1785 1790
Female Rotor Speed
rpm
1190 1193
Rotor Tip Speed
M/sec.
19.07
19.12
Inlet
Capacity
acfm
290 288 286 275
Displacement at Operating Speed
cfm
*data not available*
Volumetric Efficiency
%
*data not available*
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
2317
2420
2618
2932
Aftercooler
BTU/min.
449
450
453
454
Aftercooler Approach (standard conditions)
°F
6
Maximum Allowable Static Backpressure
in./H
2
O
0.125
Fan Motor
HP
2
Fan Motor
rpm
1790
Fan Flow
cfm
4500
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
40-100
Vent Fan Motor
HP
1/14
Aftercooler Approach to Cooling:
Water Temperature
°F
12-14
Water Flow less Aftercooler at: 50°F
gpm
*data not available*
70°F
gpm
5
6.5
7.5
8.5
90°F
gpm
10
10.5
11.5
13
Water Flow with Aftercooler at: 50°F
gpm
*data not available*
70°F
gpm
6.5
7.5
8.5
10
90°F gpm
10 11 12 14
Compressor Fluid
Total Fluid Capacity
gallons
8
Reservoir Fluid Capacity
gallons
6
Fluid Flow
gpm
21
Typical Fluid Carryover
ppm
1-3
Normal Airend Discharge Temperature
°F
190-195
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
83/78
Standard Cabinet (AC /WC)
dB(A)
76/75
Low Sound Cabinet (AC)
dB(A)
*data not available*
Содержание QSI Series
Страница 2: ......
Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...
Страница 140: ...Table of Contents Quincy Compressor QSI...