Section X- Maintenance Schedule
Interval:
Action:
Quincy Compressor-QSI
®
121
Periodically/Daily:
(8 hours maximum)
Monthly:
6 months or every 1000 hours:
Periodically/yearly:
Monitor all gauges and indicators for normal
operation.
Check fluid level.
Observe for fluid leaks.
Observe for unusual noise or vibration.
Drain water from air/fluid reservoir.
Service air filter as needed. (daily or weekly
if extremely dirty conditions exist)
Clean aftercooler and fluid cooler fins. (air-
cooled only)
Wipe entire unit down to maintain appearance.
Take fluid sample.
Change fluid filter.
Check pressure relief valve.
Go over unit and check all bolts for tight
-
ness.
Change air/fluid separator.
Change air filter.
Lubricate motors.
Test pressure relief valve for proper opera
-
tion.
Check safety (HAT) shutdown system (Con
-
tact a qualified service technician)
Содержание QSI Series
Страница 2: ......
Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...
Страница 140: ...Table of Contents Quincy Compressor QSI...