Section IV - Operating Procedures
Quincy Compressor-QSI
®
73
Number
Timers
Description
1
Remote To Local Time
Time between two remote – local requests.
2
Start/Load Time
Time between two start - load requests.
3
Unload/Load Time
Time between two unload-load requests.
4
Manual seq. Shift Up Delay
The delay due to increase in pressure to start loading the
next compressor.
5
Manual seq. Shift Down Delay
The delay due to decrease in pressure to start unloading
the next compressor.
6
Forced Time
Setting used to decide to start a stopped compressor
irrespective of the pressure algorithm.
Содержание QSI Series
Страница 2: ......
Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...
Страница 140: ...Table of Contents Quincy Compressor QSI...