Appendix A - Technical Data
124
Quincy Compressor-QSI
®
QSI 370
Standard
Full Load Operating Pressure
psig
100
110
125
150
Maximum Operating Pressure
psig
115
125
140
165
Minimum Operating Pressure
psig
75
Maximum Ambient Operating Temperature:
Less Cabinet
°F
120
With Cabinet
°F
115
Minimum Ambient Operating Temperature
°F
32
Compressor Drive Motor
HP
75 100
Rotor Diameter
mm
204
Male Rotor Speed
rpm
1785 1790
Female Rotor Speed
rpm
1190 1193
Rotor Tip Speed
M/sec.
19.07
19.12
Inlet
Capacity
acfm
372 370 368 364
Displacement at Operating Speed
cfm
403.1
404.2
Volumetric Efficiency
%
92.3
91.5
91
90.1
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
2808
2957
3184
3581
Aftercooler
BTU/min.
522
Aftercooler Approach (standard conditions)
°F
3-5
Maximum Allowable Static Backpressure
in./H
2
O
0.125
Fan Motor
HP
3
Fan Motor
rpm
1750
Fan Flow
cfm
6800
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
40-100
Vent Fan Motor
HP
1/9
Aftercooler Approach to Cooling:
Water Temperature
°F
13-18
Water Flow less Aftercooler at: 50°F
gpm
4.7
5.5
70°F gpm
7.1
8.9
90°F gpm
15.2
24.6
Water Flow with Aftercooler at: 50°F
gpm
6.2
7.3
70°F gpm
9.2
11.5
90°F gpm
19.4
29.5
Compressor Fluid
Total Fluid Capacity
gallons
15
Reservoir Fluid Capacity
gallons
11
Fluid Flow
gpm
24.5
Typical Fluid Carryover
ppm
1.5-5
Normal Airend Discharge Temperature
°F
175-195
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
83/83
Standard Cabinet (AC/WC)
dB(A)
79/79
Low Sound Cabinet (AC)
dB(A)
76
Содержание QSI Series
Страница 2: ......
Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...
Страница 140: ...Table of Contents Quincy Compressor QSI...