Appendix A - Technical Data
126
Quincy Compressor-QSI
®
QSI 600
Standard
Full Load Operating Pressure
psig
100
110
125
150
Maximum Operating Pressure
psig
115
125
140
165
Minimum Operating Pressure
psig
75
Maximum Ambient Operating Temperature:
Less Cabinet
°F
118
With Cabinet
°F
110
Minimum Ambient Operating Temperature
°F
35
Compressor Drive Motor
HP
125 150
Rotor Diameter
mm
255
Male Rotor Speed
rpm
1785 1790
Female Rotor Speed
rpm
1190 1193
Rotor Tip Speed
m/sec.
23.83
23.9
Inlet
Capacity
acfm
630 623 615 594
Displacement at Operating Speed
cfm
*data not available*
Volumetric Efficiency
%
*data not available*
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
4674
4911
5292
5972
Aftercooler
BTU/min.
1016
1018
1017
1025
Aftercooler Approach (standard conditions)
°F
6
Maximum Allowable Static Backpressure
in./H
2
O
0.125
Fan Motor
HP
5
Fan Motor
rpm
1790
Fan Flow
cfm
12200
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
40-100
Vent Fan Motor
HP
1/9
Aftercooler Approach to Cooling:
Water Temperature
°F
9-10
Water Flow less Aftercooler at: 50°F
gpm
*data not available*
70°F gpm
15 16 17 38
90°F gpm
25 27 55 38
Water Flow with Aftercooler at: 50°F
gpm
*data not available*
70°F gpm
12 14 16 27
90°F gpm
21 24 45 29
Compressor Fluid
Total Fluid Capacity
gallons
13
Reservoir Fluid Capacity
gallons
11.8
Fluid Flow
gpm
35
Typical Fluid Carryover
ppm
1-3
Normal Airend Discharge Temperature
°F
190-195
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
87/86
Standard Cabinet (AC/WC)
dB(A)
82/81
Low Sound Cabinet (AC)
dB(A)
*data not available*
Содержание QSI Series
Страница 2: ......
Страница 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Страница 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Страница 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...
Страница 140: ...Table of Contents Quincy Compressor QSI...