background image

CLICK TO CHANGE TEXT

1

AIR COMPRESSOR

EN 

OWNERS MANUAL

PAC-96-24 / PAC-96-50

Содержание PAC-96-24

Страница 1: ...CLICK TO CHANGE TEXT 1 AIR COMPRESSOR EN OWNERS MANUAL PAC 96 24 PAC 96 50 ...

Страница 2: ...cautions and warnings are to ensure your safety and protect you from harm or damage to the product All photographs and drawings in this manual are supplied by Parker Products Ltd to help you with the operation and maintenance of the product The information contained in this manual was accurate at the time of production however Parker Products Ltd may make modifications to the product without notif...

Страница 3: ...vent damage to the motor CAUTION When restarting with the reset button check the compressor for problems and check the pressure in the tank is under 0 8Mpa ALWAYS Disconnect the plug to cut off the power supply and open the outlet valve and discharge all the air in the air tank after use CAUTION For your protection if this tool is to be used outdoors it should not be exposed to rain or used in dam...

Страница 4: ...PLEASE RECYCLE WHERE FACILITIES EXIST CHECK YOUR LOCAL AUTHORITY OR RETAILER FOR RECYCLING ADVICE CONFORMS TO CURRENT SAFETY STANDARDS Triman Waste Collection Recycling Double Insulated RISK OF ELECTRIC SHOCK The compressor must be disconnected from the mains supply before removing any covers Do not use in a damp environment HOT SURFACES This compressor contains surfaces which may reach a high tem...

Страница 5: ...d become familiar with the instructions in this booklet In particular become familiar with the ON OFF control for emergency stopping ALWAYS USE EYE PROTECTION When operating the air compressor always use eye protection and make sure that other people in the work area are also using eye protection Eye protectors must provide protection from flying particles both from the front and from the side NEV...

Страница 6: ...OR PROPERLY When not in use the air compressor should be stored in a secure dry place out of the reach of children Always lock up the storage area PROTECT YOUR HEARING Ear protection should be worn when operating this compressor MAINTAIN THE AIR COMPRESSOR WITH CARE If the air compressor is damaged in any way have it repaired by a qualified service engineer EXTENSION LEAD Only use extension leads ...

Страница 7: ... be replaced prior to further use of the compressor ONLY USE WITHIN THE RECOMMENDED OPERATING TEMPERATURE RANGE This compressor should only be used in an ambient temperature of between 0OC and 25OC CLEANING AND CONDITION OF THE COMPRESSOR Keep the external surfaces of the tank clean Avoid impact damage and do not allow the tank to come into contact with abrasive or corrosive materials MOVING THE C...

Страница 8: ...HAT S IN THE BOX 15 WHAT S IN THE BOX MAIN BODY COMPRESSOR FAN COVER PRESSURE SWITCH PRESSURE GAUGES REGULATING VALVE SAFETY VALVE DISCHARGE PIPE AIR TANK DRAIN VALVE ALL PRE ASSEMBLED AIR FILTER 1x WHEELS 2x AXLE KIT 2x OIL PLUG 1x OIL 1x ...

Страница 9: ...DUCT FEATURES PRODUCT FEATURES POWER SWITCH DRAIN VALVE AIR TANK FAN COVER WHEELS OIL LEVEL SIGHT WINDOW RUBBER SUPPORT FOOT OUTLET VALVE OIL SUMP BOLT PRESSURE GAUGES OIL FILER PLUG AIR FILTER REGULATOR HANDLE ...

Страница 10: ...NG Do not run the machine without the air filter in place i NOTE Identify all parts before proceeding with the assembly of machine 1 REMOVE AIR FILTER TRAVEL PLUG Remove the white plastic travel plug from the air filter location hole It is important that the white plug is removed from the machine and the air filter is fitted before running the machine 2 ATTACH AIR FILTER With the white plastic tra...

Страница 11: ...the plug somewhere safe while refilling with oil as to not lose it Pour fresh oil into the oil filler hole If required use a small funnel to make the process easier it is recommended that ISO 46 Compressor Oil is used in this machine WARNING Do not run the compressor without sufficient oil inside This will damage the machine beyond repair WARNING Open the outlet valve run the compressor for 10 min...

Страница 12: ...fied repair centre every six months to ensure they are in correct working order i 1 POWER SWITCH The power switch is located on top of the machine on the pressure switch housing 2 POWER SWITCH ON 1 Pull the power switch upwards to turn the machine into the ON 1 position 3 POWER SWITCH OFF 0 Push the power switch down to turn the machine into the OFF 0 position NOTE Push the power switch down to tu...

Страница 13: ...ure switch It stops automatically as the pressure increases to the maximum and restarts as pressure decreases to the minimum The rated pressure has been adjusted during the manufacturing process alter this pressure with caution To gain access to the adjustment screw simply remove the pressure switch cover loosen the screw on top of the cover and slide the cover off Before proceeding ensure the pow...

Страница 14: ...h a thermal overload device with a thermal reset switch This operates as a safety device to protect the motor if it is overloaded or overheats for any reason The thermal overload automatically cuts the power and the thermal reset button will pop out indicating that an internal electric safety device has tripped shutting the motor off Once the motor has cooled sufficiently it can be re started usua...

Страница 15: ...aintenance operation stop the air compressor cut off the power supply disconnect from the mains and discharge all the air in the tank Renew lubricating oil after the first ten working hours Check the oil level through the sight glass after every twenty working hours the oil level should be within the red circle of the sight glass Replenish if necessary You can replenish by unbolting the sump bolt ...

Страница 16: ...drain valve is located on the bottom of the tank Once the compressor has been turned off and all pressure has been vented from the tank turn the drain valve to remove any condensation from inside the tank WARNING Corrosion inside the tank could lead to the tank exploding when under pressure WARNING Air tank should be checked by a certified repair centre every twelve months 2 REMOVE CONDENSATION FR...

Страница 17: ... gauges should be checked by a certified repair centre every six months NOTE Air tank should be checked by a certified repair centre every twelve months 2 AIR TANK Make sure there is no rust on the air tank and the air tank is not damaged Have the thickness of the tank checked by a certified repair centre every year to ensure the tank thickness is not less than 2 1mm THIS PAGE HAS INTENTIONALLY BE...

Страница 18: ... tighten Foreign body in the main compressor Check and clean Piston locking valve seat worn torn Replace gasket Moving parts seriously worn Repair or replace TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Pressure insufficient or discharge capacity decreased Motor running too slow Check and remedy Air filter clogged clean or replace Safety Valve leaking Check and adjust Discharge pipe leaking Che...

Страница 19: ...SURE SWITCH 1 41 LOCK BOLT M8 x 2 4 4 58 WASHER 8 1 8 CYLINDER GASKET 1 25 PRESSURE GAUGE 2 42 SEALED RING 18 x 2 4 2 59 NUT M8 1 9 PISTON RING 3 26 QUICK COUPLERS 2 43 STEM RP 1 2 2 60 PISTON PIN 1 10 PISTON 1 27 REGULATOR VALVE 1 44 DISCHARGE PIPE 1 61 FAN COVER 1 11 CIRCLIP 2 28 DISTRIBUTOR 1 45 STARTER 1 62 COLUMN 2 12 CONNECTING ROD 1 29 RELEASE PIPE 1 46 BEARING 6203 1 63 AIR FILTER 1 13 CRA...

Страница 20: ...cts Ltd or an authorised repair agent If any fault is caused by defective materials or quality of build repair will be carried out free of charge However this guarantee does not apply in the case of normal wear and tear nor any damage caused by misuse accident or any repair from an unauthorised agency The product is to be used only for its prescribed purpose any other use is deemed to be a case of...

Страница 21: ...l Number 2020 Conforms to the following Directives Machinery Directive 2006 42 EC Low Voltage Directive 2014 35 EU Manufacturer s authorised representative within the EC Parker Products Ltd Richmond Park Richmond Road Louth LN11 0FU Conforms to the requirements of the Directives as indicated and the following harmonised standard s EN 1012 1 2010 AfPS GS 2014 01 PAK Technical file complied by Parke...

Страница 22: ...WWW PARKERBRAND CO UK PAC 96 24 PAC 96 50 Rev 1 1 March 2020 ...

Отзывы: