5–Validation Methods for DCB and FCoE
Validation Step 1—Verify PFC and ETS Parameters
51031-00 A
5-3
pfc_enable value is the same for the adapter, switch, and targets.
Application type-length-value (TLV) contains one entry for FCoE
protocol and one entry for FCoE initialization protocol (FIP). The
user_priority_map should be the same for the adapter, switch,
and targets.
Priority group TLV for the switch contains the ETS bandwidth
allocation configured at the switch console.
If IEEE DCBX version 1.4 or later is used, then verify the following:
Converged Network Adapter and Target Willing bit (W) is ON,
while the Switch W bit is OFF.
pfc_enable value is the same for the adapter, switch, and targets.
Application TLV contains one entry for FCoE protocol and one
entry for FIP. The user_priority_map should be the same for the
adapter, switch, and targets.
ETS Recommendation TLV for the switch contains the bandwidth
allocation per priority as configured on the switch console.
ETS Configuration TLV for the adapter and target contain the
same bandwidth allocation per priority as the switch.