2–Planning
Where and How to Deploy
2-2
51031-00 A
Currently, a Converged Network Adapter must always be connected to a switch
that has DCB. There are two types of switches that have DCB: a DCB switch and
an FCoE switch. The DCB switch has enhanced Ethernet support, but does not
have Fibre Channel forwarder (FCF) capabilities, and does not support the
conversion of Fibre Channel frames to FCoE frames. A DCB switch supports
converging-Ethernet-based protocols, but does not support Fibre Channel
protocols. The DCB switch requires an external device to manage Fibre Channel
and FCoE functions. An FCoE switch supports both DCB and Fibre Channel.
There are three ways to connect Fibre Channel storage to a unified fabric:
Converged Network Adapter > FCoE switch > Fibre Channel switch >
Fibre Channel storage
The adapter connects to the FCoE switch with Ethernet infrastructure, and
the FCoE switch connects to storage through a Fibre Channel switch
(Martin, 2010). This is the most common implementation in today's data
centers because the Fibre Channel switch and SAN storage are typically
already in place.
Converged Network Adapter > DCB switch > FCF > Fibre Channel
switch > Fibre Channel storage
The DCB switch requires an external device to provide FCF function to the
attached Fibre Channel storage. This approach is not as common because
most data centers do not have an FCF device, and will acquire an FCoE
switch to connect to their Fibre Channel Infrastructure.
Converged Network Adapter > FCoE switch > FCoE storage
This implementation is not common because, most data centers use Fibre
Channel SAN storage. As more storage vendors deliver FCoE storage,
more pilot projects will support direct Ethernet connection from the FCoE
switch to FCoE-capable storage controllers (Martin, 2010).
In all cases, Ethernet LAN and iSCSI storage connect directly to Ethernet ports on
the DCB or FCoE switch.
The reference architecture, described in
Section 3
, uses direct-attached native
FCoE storage and Fibre Channel switch-connected SAN storage.
Section 4
describes the implementation of the reference architecture and
Section 5
describes the validation.
Содержание Storage Networking (Unified Fabric Pilot)
Страница 10: ...Preface Documentation Conventions x 51031 00 A...
Страница 12: ...1 Overview 1 2 51031 00 A...
Страница 16: ...3 Architecture Reference Architecture Description 3 2 51031 00 A Figure 3 1 Reference Architecture Diagram...
Страница 18: ...3 Architecture Reference Architecture Description 3 4 51031 00 A...
Страница 66: ...A Hardware and Software QLogic 5800V Series Fibre Channel Switch A 4 51031 00 A...
Страница 72: ...C References C 2 51031 00 A...
Страница 75: ......