4–Installation
Equipment Installation and Configuration
4-8
51031-00 A
10.
Configure Ethernet port 1/3 to enable VLAN-1002-tagged FCoE traffic and
VLAN-2-tagged NIC traffic.
interface Ethernet1/3
switchport mode trunk
switchport trunk allowed vlan 2,1002
spanning-tree port type edge trunk
interface vfc3
bind interface Ethernet1/3
no shutdown
11.
Display the configuration to confirm that it is correct.
switch(config)#
sh policy-map system
Type network-qos policy-maps
===============================
policy-map type network-qos policy1
class type network-qos class-nic match qos-group 2
pause no-drop
class type network-qos class-fcoe match qos-group 1
pause no-drop
mtu 2240
class type network-qos class-default match qos-group 0
mtu 1538
Service-policy (qos) input: policy1
policy statistics status: disabled
Class-map (qos): class-nic (match-any)
Match: cos 0
set qos-group 2
Class-map (qos): class-fcoe (match-any)
Match: cos 3
set qos-group 1
Class-map (qos): class-default (match-any)
Match: any
set qos-group 0
Service-policy (queuing) input: policy1
policy statistics status: disabled
Class-map (queuing): class-nic (match-any)
Match: qos-group 2
Содержание Storage Networking (Unified Fabric Pilot)
Страница 10: ...Preface Documentation Conventions x 51031 00 A...
Страница 12: ...1 Overview 1 2 51031 00 A...
Страница 16: ...3 Architecture Reference Architecture Description 3 2 51031 00 A Figure 3 1 Reference Architecture Diagram...
Страница 18: ...3 Architecture Reference Architecture Description 3 4 51031 00 A...
Страница 66: ...A Hardware and Software QLogic 5800V Series Fibre Channel Switch A 4 51031 00 A...
Страница 72: ...C References C 2 51031 00 A...
Страница 75: ......