5–Validation Methods for DCB and FCoE
Validation Step 5—ETS Verification
5-22
51031-00 A
Figure 5-23
shows how to enable a cross-port analysis in Expert's Edit /
Preferences dialog. In a cross-port analysis, Expert ensures that each frame is
making its way across the switch, and reports frame losses and the latency
through the switch. In addition, Expert reports aborted sequences and
retransmitted FCoE, iSCSI, and TCP traffic. Expert reports all symptoms and
network anomalies indicating frame losses and performance degradation.
Figure 5-23. Enabling Cross Port Analysis in Expert
However, because the FCoE traffic has PFC enabled, the decrease in FCoE traffic
is a result of the pause frames sent by the switch to the storage device.
Figure 5-24
shows pause requests and pause releases sent only to the storage
port.
Figure 5-24. Switch Issue Pause to Storage
Содержание Storage Networking (Unified Fabric Pilot)
Страница 10: ...Preface Documentation Conventions x 51031 00 A...
Страница 12: ...1 Overview 1 2 51031 00 A...
Страница 16: ...3 Architecture Reference Architecture Description 3 2 51031 00 A Figure 3 1 Reference Architecture Diagram...
Страница 18: ...3 Architecture Reference Architecture Description 3 4 51031 00 A...
Страница 66: ...A Hardware and Software QLogic 5800V Series Fibre Channel Switch A 4 51031 00 A...
Страница 72: ...C References C 2 51031 00 A...
Страница 75: ......