background image

ER

S 01

GB  -  Operation and Maintenance Manual 

2

GB 

-  Before use, please read ”General use and maintenance manual” carefully.

The manuals which are enclosed with the product must be kept throughout the product’s entireservice life.

Electronic Flame Controller ERS 01

Electronic Flame Controller ERS 01

Содержание ERS 01

Страница 1: ...GB Before use please read General use and maintenance manual carefully The manuals which are enclosed with the product must be kept throughout the product s entireservice life Electronic Flame Control...

Страница 2: ...Closing the casing step one 7 Fig 11 Closing the casing step two 7 Fig 12 User log in screent 7 Fig 13 Wrong password message 7 Fig 14 Controller and welcome screen 10 Fig 15 Main screen 10 Fig 16 Op...

Страница 3: ...ded to get acquainted with a local system of utilization of electric and electronic products It is recommended to act accordingly to local regulations and not to throw used products to containers toge...

Страница 4: ...damaged In no circumstances can the design of the regulator be modified Keep the regulator out of reach of children Do not assemble the device when it is energized Operating the device which is defec...

Страница 5: ...ing of the cable and bushing tip should be within the range of 8 10 mm Cable is inserted into a terminal by pushing a button on this terminal with a flat screwdriver inserting the cable tip with a col...

Страница 6: ...ure is exceeded The throttle should be calibrated together with the regulator Calibration process is described in chapter 12 4 Calibration process can be performed outside the fireplace by connecting...

Страница 7: ...parameters may result in the malfunction of the fireplace or damage Description of parameters Tmin Parameter limiting the possibility of presetting minimum temperature of exhaustion gases Tzadmin val...

Страница 8: ...oller s throttle in phase I of lighting process Td lighting I differentiation time of PID algorithm for controlling the flame controller s throttle in phase I of lighting process T lighting I optimum...

Страница 9: ...ount of fuel The intake air throttle is opened at 60 100 and exhaust gases temperature is decreasing Fuel amount which is supplied to the fireplace furnace is insufficient to maintain temperature of f...

Страница 10: ...adout The regulator can be operated with the use of provided or adapted remote control Adaptation procedure is described in chapter Handling Remote control menu Press the switch in order to enable dis...

Страница 11: ...ade by a menu system Activating MENU is also performed by pushing or turning the knob in the main window so as to select the MENU icon Push the knob according to the following diagram Fig 19 Activatin...

Страница 12: ...of a fireplace the user can select another temperature out of 11 set temperature options by increasing or reducing the temperature s value Attention It is not recommended to use low temperature range...

Страница 13: ...rature of the automatic mode of operation the flame controller switches into the second stage of lighting process 10 1 2 Lighting phase II In the second phase of lighting flame controller slowly shuts...

Страница 14: ...nabling to open the throttle and enable edition by pushing the knob In edition mode blinking value turn the knob in order to change position of the air throttle there is no need to confirm the value F...

Страница 15: ...the regulator will calculate temperature steps Value of this parameter is assigned to position 1 of temperature presetting steps Tset max Maximum preset temperature of exhaust gases in the fireplace...

Страница 16: ...o II automatic mode stage II activated the throttle positions on the fireplace temperature fall to the value of Toperation dT auto II automatic mode stage II activated the difference of temperature in...

Страница 17: ...ation manual If no access code is provided 0000 value will be left the regulator will show the read only parameter values included in the menu Important Parameters should be modified only by persons w...

Страница 18: ...tion is used in dark compartments The encoder s backlight pulsing is maintained after switching the regulator off 13 2 Handling Screen menu This menu provides access to set screen options Turning the...

Страница 19: ...ff screen When disabling function is confirmed by selecting YES the intake air throttle will be set to Throt off put down parameter value thisparameterisdescribedinchapter Burningoptions However if th...

Страница 20: ...roducts supplied may therefore differ in specification colour and type of accessories from those illustrated and described in the brochure J tul Polska Sp z o o Polska 80 871 Gda sk ul Twarda 12 A www...

Отзывы: