1-6
VIBXPERT Balancing 11.2010
Safety
ATTENTION!
WARNING!
Safety
You must carefully read and understand the safety instructions in the
VIBXPERT operating manual (VIB 9.805.G) as well as the following
safety instructions for balancing before starting work with the
measurement device.
• When assembling measurement components, make sure that no
holders, cables, etc. project into the range of movement of
rotating machine parts.
• The respective manufacturer's instructions must be followed
when mounting balancing weights.
Make sure that attachment points for balancing weights to be
welded on are clean; clamp the ground electrode of the welding
device onto the rotor and not onto the machine.
For balancing weights that need to be screwed on, the maxi-
mum permitted RPM of the motor must be observed.
• The machine must be disconnected in order to work on the
rotor and must be secured against being switched on again in
accordance with the applicable regulations.
• Before the first measurement (initial run), it is important to
ensure that the preparatory activities have been carried out
correctly and completely. In addition to the assembly of
measurement components, particular attention must be paid to
the correct input of parameters in the machine setup. If an
incorrect rotor mass is entered, a trial weight that is too large
may be calculated as a result. This could have serious conse-
quences for personnel and machine!
• No one is allowed to remain in the radial vicinity of the rotor
during balancing runs. This area must be properly secured
against unauthorized entry. If the trial weight of the rotor on a
running machine detaches, there is a risk of fatal injury in this
area!
• If the rotor is in a protective housing, any gaps in the housing
must be closed before switching on the machine.
• The permitted switch-on frequency of the machine may not be
exceeded. Otherwise, the motor could be damaged.
• The cause of the imbalance must be determined before balanc-
ing, and must be corrected if necessary (e.g. remove any caking
on the rotor, weld any cracks on the impeller or replace the
impeller).
Содержание VIBXPERT Balancing
Страница 43: ...3 5 VIBXPERT Balancing 11 2010 empty page ...