![PRÜFTECHNIK VIBXPERT Balancing Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/pruftechnik/vibxpert-balancing/vibxpert-balancing_operating-instructions-manual_1621895037.webp)
2-29
VIBXPERT Balancing 11.2010
Measurement setup
When creating a new measurement setup, the following parameters
can be edited:
F
ILTER
:
0.5 / 1 / 2 / 10 Hz
; select "10 Hz" as the lowest frequency if the
machine RPM is more than 600 RPM and the machine is placed on
a flexible foundation.
A
VERAGING
:
1 - 20
; the number of averages is automatically increased
to the maximum value if the indicator shows strongly varying
imbalance.
T
IME
SYHNCHRONOUS
AVERAGING
: In this type of averaging, the time signals
of each individual rotation are averaged to reduce non-synchro-
nous components in the signal. The calculated phase values are
likewise averaged to increase the stability of the phase vector. The
parameters for the phase averaging correspond to the settings
under "Average type / Number of measurements' (see above). The
number of time synchronous averages is either RPM-dependent,
user-defined or unrestricted:
‘Auto’: Time synchronous number of averages is a function of the
rpm*.
‘Manual’: Time synchronous number of averages can be entered
(max. 254).
‘Unrestricted’: Each individual measurement is averaged with the
preceding individual measurement. The longer the measurement
takes, the more stabile the final result. This average type is
generally used for balancing. The measurement must be stopped
using the joystick.
O
RDER
:
1 - 5
; order filters enable the balancing at RPM harmonics of a
higher order; these special cases can occur in special machine
configurations.
M
EASUREMENT
RANGE
: The measurement range for the analog channel
(A/B) can be automatically
matched to the input signal
('Auto') or set to fixed. When set
to ‘[Value] / Auto-Up’, the mea-
surement range is automatically
increased when the upper limit is
exceeded.
Balancing: Measurement setup
Parameters in the
measurement setup