2-7
VIBXPERT Balancing 11.2010
Balancing: Preparations
5. Mount the laser trigger sensor with the trigger bracket (VIB
6.632) according to the following figure. Installation notes:
• The machine is switched off during the installation.
• The maximum distance to the shaft is 2 meters.
• To adjust the device, the laser beam is pointed toward the
measurement mark while the machine is at a standstill. As far
as possible, the laser beam should be perpendicular to the shaft
surface and shaft axis.
Trigger sensor assembly
R
R
F
E
S
C
MEN
U
HE
LP
Trigger Bracket
(VIB 6.632)
Vibration transducer on
the magnetic adapter
(VIB 6.142R + VIB 3.420)
Reflective tape
(VIB 3.306)
Laser Trigger Sensor
(VIB 6.631)
Trigger cable
(VIB 5.432-2.9)
6. Connect the vibration transducer and the trigger sensor to the
measurement instrument.
Permissible angle deviation :
± 45° (reflective marker)
± 15° (contrast marker)
Laser trigger sensor
Shaft
(top view)
Содержание VIBXPERT Balancing