2-21
VIBXPERT Balancing 11.2010
Balancing: Options
Removing the balancing weight
If the balancing weights cannot be attached to the rotor by clamping,
welding, screwing or similar, the imbalance can also be compensated
by grinding material off the rotor. To do this, select the "Trial/ Trim
masses -> remove" option in "Tools" menu (see below). VIBXPERT
then calculates the "Balancing weights" as negative masses.
Checking functions
In order to ensure that the balancing procedure provides reliable and
usable results, VIBXPERT has the following check functions in the
"Tools" menu:
C
HECKING
SPEED
Before each measurement VIBXPERT checks whether the mea-
sured RPM is stable. An appropriate error message appears if the
RPM varies excessively.
C
HECKING
BAD
INFLUENCE
The change of the imbalance indicator is checked; if the change is
too large/too small, an appropriate message appears. Return to the
previous balancing run and reduce or increase the weight used.
R
ECALCULATING
THE
COEFFICIENT
The coefficient for calculating the balancing weight can be taken
over from the trial run (setting: "No") or from the previous
balancing run (setting: "Yes").
C
HECKING
STABILITY
The stability of the imbalance indicator is checked during the
measurement. If the imbalance indicator is unstable and the 'Auto-
average' option is active (s. p. 2-28), VIBXPERT automatically
increases the selected number of averages in the measurement
setup. An appropriate message appears if the maximum number of
averages is reached.
"Remove balancing weight"
Grinding off rotor material
Содержание VIBXPERT Balancing
Страница 43: ...3 5 VIBXPERT Balancing 11 2010 empty page ...