2-19
VIBXPERT Balancing 11.2010
Balancing: Options
Options for balancing
The following options are available in the trial run and the trim runs:
Checking the measurement setting
• Press the MENU button and click on "Task Manager".
• Mark the respective setup, press the MENU button and click on
"Show" to display the specified parameters. To add a new measure-
ment setup, follow the instructions on page 2-29.
Changing the correction mode
The correction mode describes how the balancing weight is attached
to the rotor. Normally the correction mode is set to 'Free & add', i.e.
the weight can have any mass and be placed at any angular position.
• Press the MENU button in the data screen and click on "Tools".
The following correction modes are available additionally:
– Fixed location
– Fixed weight
– Meas. tape
Fixed location
To attach the balancing weight only at specific positions on the rotor
(e.g. on the blade of a ventilator), select the "Fixed location"
correction mode. Then enter the "Number of locations" on the rotor.
VIBXPERT calculates two masses in the balancing runs which are to
be placed at two of the permanently specified positions. Position or
blade #1 corresponds to the 0° position and should be selected as a
reference mark for the trigger. In the data screen, the angular
position is displayed for each fixed location.
"Fixed location" correction mode
Left:
Changing correction mode in
"Tools"
Right:
"Fixed location"
Setting the number of fixed locations