2-15
VIBXPERT Balancing 11.2010
Balancing: 2-plane
Balancing in two planes
In principle, the process here corresponds to the previous section.
Therefore, only the specific features of balancing in two planes are
described in the following section:
Overview of the measurement procedure
Plane A? : Determination of the measurement and balancing plane A.
0.
Initial imbalance: Measurement in plane A and plane B
1A. Trial run: Recommendation for trial weight in plane A;
measurement in plane A and plane B with trial weight in plane A
1B. Trial run: Recommendation for trial weight in plane B;
measurement in plane A and plane B with trial weight in plane B
2.
Balancing run: Recommendation for balancing weight in plane A
and plane B; measurement in plane A and plane B
....
N. Balancing run ...
Determining the measurement plane & balancing plane A
1. Activate the balancing mode and open the "2 planes" tab.
2. Click on the rotor graphic which corresponds to the rotor type.
3. Select plane A:
- Next connect the transducer which is mounted in measurement
plane A to measurement channel A (see "Overview").
Measuring the initial imbalance in plane A and plane B
1. Switch the machine on and start the initial run.
Measurement plane A
Balancing plane A
Left:
Selection screen - rotor type
Right:
Setting of plane A
Содержание VIBXPERT Balancing
Страница 43: ...3 5 VIBXPERT Balancing 11 2010 empty page ...