2-12
VIBXPERT Balancing 11.2010
First, VIBXPERT records the RPM. The green LED flashes with each
trigger pulse. If the RPM varies too much, a warning message
appears.
Finally, the instrument measures the amplitude and phase of the
RPM synchronous vibration. If the values are unstable, the average is
automatically increased.
3. If the measurement values are stable, press the joystick to stop the
measurement (see previous page).
To repeat the measurement, press the joystick again.
4. Switch the machine off.
Trial run
1. Move the joystick to the right to open the data screen for the trial
run.
2. Enter the mass and fixing angle for the trial weight.
- Click on the mass or angle field under the rotor graphic. The active
field is highlighted in black.
- Enter the respective value in the number editor and confirm the
entry with MENU - 'OK'.
3. Move the joystick to the right until the next screen appears.
If the trial mass is applied at random, there is a risk of increased
imbalance and thus an increased vibration load. Especially if
vibration loads are already very high, this may result in further
machine damage.
4. Switch the machine on.
Balancing: 1-plane
ATTENTION
Left:
Measure 'Initial' run
Right:
Enter mass and angle for trial run