4
Assembly and installation
n
User qualification, mechanical installation: trained and qualified
Chapter 1.2 ‘User qualification’ on page 7
n
User qualification, hydraulic installation: trained and qualified
Chapter 1.2 ‘User qualification’ on page 7
n
User qualification, electrical installation: electrical technician
Chapter 1.2 ‘User qualification’ on page 7
NOTICE!
Drying agent
Possible malfunction of the sensor due to moisture
in the device.
Fit the bag of dessicant before initial commis‐
Chapter 6.1 ‘Inserting the dessi‐
NOTICE!
Installation site and conditions
– Only undertake installation (electrical) after
assembly (mechanical) has been completed.
– Ensure that there is unimpeded access for
operation.
– Make sure that the fastening is secure and pro‐
tected from vibrations.
– Avoid direct sunlight.
– Permissible ambient temperature for the
sensor at its installed position: 1 ... 50 °C at
max. 95 % relative air humidity (non-con‐
densing).
– Consider the permissible ambient temperature
of the connected components.
– Only use the device with water that is free of
corrosive or hazardous substances.
Install the device on a suitable, vertical and flat wall that can
bear the weight of the device.
INFORMATION! Install the device in a favourable position for
reading and operation, preferably at eye level.
INFORMATION! Leave sufficient clearance for the cables and any
necessary work.
INFORMATION! Dispose of all packaging material in an environ‐
mentally responsible way. All packaging components carry the cor‐
responding recycling code .
Assembly and installation
13