70284701
95
Section 7 Electronic Control Troubleshooting
WILL NOT HEAT – STEAM – EDC MODELS
(Sheet 2 of 2)
T097D
Replace the stove
limit.
Is there voltage to the
output side of the stove
limit?
Correct wiring to
steam valve coil.
Is there voltage across
steam valve coil?
Repair or replace
steam valve.
Does steam valve
operate properly?
Check for proper
steam supply.
Correct if necessary.
Is heat produced?
NO
YES
NO
YES
NO
YES
NO
YES
Unit operational.
T097D