28
70284701
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
33. COMPLETE GAS VALVE ASSEMBLY
Refer to Figure 18.
a. Remove gas valve cover.
b. Disconnect gas valve wire connections.
c. Disconnect gas valve pipe union holding gas
shut-off valve to gas valve nipple.
d. Remove screws holding gas valve to gas valve
bracket and remove valve.
IMPORTANT: When reinstalling gas valve, purge
air and sediment from gas service line before
connecting to tumbler. Purge remaining air until
odor of gas is detected, then tighten connection. Use
pipe compound resistant to action of L.P. gas on all
pipe threads.
Figure 17
TMB35S
75%
TMB35S
STOVE
LIMIT
THERMOSTAT
THERMOSTAT
ATTACHING
SCREW
STOVE
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use an
open flame to check for gas leaks!
W310
WARNING
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......