Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
55. LOADING DOOR STRIKE
Refer to Figure 31.
The door strike must be adjusted so that sufficient
tension holds loading door closed against the force
of a load tumbling against it. The door is properly
adjusted when 8-15 lbs. (3.60-6.75 kg) of pull is
required to open door.
To adjust, open door, loosen jamnut and turn door
strike screw in or out as required. Retighten
jamnut.
Figure 31
T280SE3A
LOADING
DOOR
JAMNUT
DOOR STRIKE
SCREW