Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
29. REAR CYLINDER SEAL
Refer to Figure 14.
a. Remove cylinder assembly. Refer to
Paragraph 27.
b. Remove seal from seal support on rear panel.
c. Degrease area where new seal is to be placed.
Scrape any remaining adhesive remnants from
seal support.
d. Apply generous amount of adhesive into seal
support.
e. Carefully install seal into adhesive surface.
Apply pressure until glue is able to support seal
and hold it in position.
For personal safety use degreaser/solvent
only in a well ventilated area away from any
open flames or sources of ignition.
W242
WARNING
Figure 14
TMB1791S
CENTER
CYLINDER
SEAL
REAR
CYLINDER
SEAL
SUPPORT
TRUNNION
ASSEMBLY
CYLINDER
ASSEMBLY
BEARING
WASHER
PALNUT
JAM NUT
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......