70
70284701
Section 7 Electronic Control Troubleshooting
WILL NOT RUN – ELECTRIC – ROTARY COIN DROP
(Sheet 3 of 3)
T074D
Is there voltage at
terminals 1 & 4 of
the cylinder motor?
Correct wiring
between cylinder
motor and contact
9 on the motor
control relay.
NO
Does the cylinder
motor run?
Replace the
cylinder motor.
NO
The cylinder and
fan motors are
operational.
YES
YES
COLUMN 1
voltage across
terminals 6 & 9 of
motor control relay?
NO
YES
Replace motor
control relay.
T074D
Is there