70284701
33
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
40. HEATER ELEMENT
(Electric Models)
Refer to Figure 23.
a. Remove three screws holding connector cover
in place. Remove guard.
b. Remove nuts attaching element wires and
jumper bars to elements. Disconnect element
wires.
c. Remove six screws holding element guard to
back of heater box. Remove guard.
d. Remove element attaching screw holding
element to the left side of stove (viewed from
rear of tumbler).
e. Slide element to right and pull left side of
element down and out to the left to remove
element (viewed from rear of tumbler).
Figure 23
TMB1757S
HEATER
ELEMENT
CONNECTOR
COVER
ELEMENT
GUARD
ATTACHING
SCREW
ELEMENT
ATTACHING
SCREW
NUT
JUMPER
BAR
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......