70284701
55
Section 7 Electronic Control Troubleshooting
WILL NOT START – GAS – ROTARY COIN DROP
(Sheet 2 of 2)
T087D
Correct wiring
between 2A of start
switch and COM of
lint panel switch.
Is there voltage at
2A of the start
switch?
Is there voltage at
terminal 7 of the
motor relay?
NO
YES
NO
YES
Correct wiring
between 7 of motor
relay and COM of
lint panel switch.
Refer to NO
MOTOR RUN
(run circuit).
Is there voltage to
H1-2 on TMR1
board?
STEP 1
Correct wiring
between
H1-2 and
output of
secondary
fuse.
With vend price
satisfied is there
voltage across N.C. &
COM of switch A?
NO
YES
YES
NO
Replace switch A.
Is there voltage across
the timer motor?
Is there voltage across
H1-6 & H1-8 of
TMR1?
Correct wiring
between timer motor
and COM on switch
A.
NO
YES
Correct wiring
between H1-6 and
COM on switch A.
Is there voltage across
H1-2 & H1-3 of
TMR1?
NO
YES
Is there voltage to N.O.
of door switch?
Replace TMR1.
YES
NO
Correct wiring
between N.O. of
door switch and
H1-3 of TMR1.
Continue at step 3
on previous page.
YES
NO
Does coinmeter timer
motor advance?
YES
NO
Replace timer
motor.
STEP 2
Note: Following tests
are conducted with
vend price satisfied.
T087D
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......