Section 7 Electronic Control Troubleshooting
WILL NOT START/CONTINUE RUNNING – OPL MICROPROCESSOR CONTROL
(Sheet 3 of 3)
T009D
Is there voltage
across terminals 1 & 4 of
the cylinder motor?
Does the cylinder
motor run?
Correct the wiring
between the
cylinder motor and
control relay.
Replace cylinder
motor.
YES
YES
NO
NO
Unit operational.
NOTE: For three phase high voltage (380 volts or
higher), the cylinder and fan motors are supplied L1, L2,
L3 through the motor relay terminals T1, T2, T3. Make
the appropriate voltage checks while doing trouble
shooting.