70284701
15
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Section 4
Grounding
Grounding Instructions
This tumbler must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing the path of least
resistance for electric current. This tumbler must be
connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
NOTE: To ensure protection against shock, this
tumbler MUST be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 or the latest edition of the
Canadian Electrical Code, Part I and/or local codes.
Electrical work should be done by a qualified
electrician.
IMPORTANT: To avoid a short to ground on the
control transformer line, or voltage output that
could run the control or cause it to run on a reduced
voltage; DO NOT connect a “High Leg” or “Stinger
Leg” to a single phase machine with an electrical
supply coming from a three phase service. A “High
Leg” or “Stinger Leg” on three phase machines
should be connected to L3.
To reduce the risk of fire and electric shock, check with a qualified serviceperson for proper
grounding procedures. Improper connection of the equipment grounding conductor may result
in a risk of electric shock.
W068R1
WARNING
All electrical connections should be made
by a qualified electrician.
To reduce the risk of electrical shock, de-
energize the electrical circuit being
connected to the tumbler before making any
electrical connections. Never attempt to
connect a live circuit.
W070
WARNING
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......