70284701
37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
49. FAN
Refer to Figure 27.
a. Remove four nuts and six screws holding fan to
rear of tumbler.
b. Tip fan up from bottom to remove.
c. Remove jamnut and palnut holding fan to
motor shaft. Refer to Figure 28.
d. Slide fan off shaft.
NOTE: Before attempting to service fan, always
remove thermistor to prevent damage.
50. FAN MOTOR ASSEMBLY
Refer to Figure 28.
IMPORTANT: Before attempting to service fan,
always remove thermistor to prevent damage.
a. Remove six screws and four nuts holding fan
motor mounting plate to cabinet.
b. Remove motor mounting plate, fan assembly
c. Remove palnut and jamnut from motor shaft
and remove fan from motor shaft.
d. Remove bolts holding mounting plate to motor
and remove motor.
Figure 27
T305SE1A
FAN
MOTOR
Figure 28
TMB1850S
FAN
MOTOR
MOTOR
SHAFT
MOUNTING
PLATE
FAN
JAMNUT
PALNUT
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......