70284701
13
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
9. CLOTHES DO NOT DRY
10. TUMBLER OVERHEATING
POSSIBLE CAUSE
TO CORRECT
Not enough heating time allocated for the load.
• Start cycle again with enough time to dry load.
Burner does not ignite.
• Refer to Paragraph 6.
Too much water in articles being dried.
• Remove excess water.
Clothes load too large.
• Remove part of load. Maximum load is 25 pound dry
weight (cotton load) for 25 pound Tumbler, etc.
Improper or inadequate exhaust system.
• Refer to Installation Manual for exhaust system
requirements.
Burner ignites and goes out repeatedly.
• Refer to Paragraph 7.
Drying selector improperly set.
• Set selector for higher setting.
Incorrect voltage.
• Refer to Installation Manual for electrical requirements.
Inadequate make-up air.
• Refer to Installation Manual for make-up air
requirements.
Exhaust duct to the outside blocked.
• Clean duct to remove blockage.
Clogged lint screen.
• Clean lint screen.
Inoperative thermistor
• Replace thermistor.
Exhaust damper binding.
• Adjust damper so it turns freely.
POSSIBLE CAUSE
TO CORRECT
Incorrect main burner orifices.
• Obtain and install correct orifices.
Gas pressure too high or low.
• Adjust gas pressure as specified on serial plate.
Inadequate make-up air.
• Refer to Installation Manual for make-up air
requirements.
Lint buildup.
• Clean lint compartment. Check damper for lint
accumulation. Check ductwork for lint build-up.
Restricted or inadequate exhaust system.
• Remove obstruction or lint build up from exhaust
ductwork. Refer to Installation Manual for exhaust
system requirements.
Inoperative thermistor.
• Check wiring to ensure thermistor is connected. Replace
thermistor if necessary.
Exhaust damper binding.
• Adjust damper so it turns freely.
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......