70284701
39
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Section 6
Adjustments
52. LEVELING LEGS
NOTE: Keep the tumbler as close to the floor as
possible. All legs must rest firmly on the floor so
weight of tumbler is evenly distributed. Tumbler
must not rock.
a. Check front to rear level by rotating clothes
cylinder until one of the cylinder ribs is at the
bottom. Place a level on the rib. Adjust legs as
necessary.
NOTE: The front of the tumbler should be slightly
higher than the rear (approximately 1/8 inch,
3.18 mm). This will prevent the clothes, while
tumbling, from wearing on the door glass gasket.
b. Check side to side level by placing a level on
front and rear of top panel. Adjust legs as
necessary.
IMPORTANT: Do not remove plastic caps covering
leveling legs in lint compartment.
53. AIRFLOW SWITCH ADJUSTMENT
The airflow switch is set at the factory for proper
operation. No adjustment necessary.
Содержание D11
Страница 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Страница 2: ......
Страница 10: ...8 70284701 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 18: ...16 70284701 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 44: ...42 70284701 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 159: ......
Страница 160: ......