Commander T Series PB# 4100032
Rev.C 03/12
PowerBoss, Inc. Copyright 2011
Page 63
PREVENTATIVE MAINTENANCE
NOTE: Ten (10) gallons (US) of fluid are required.
6. Check the dipstick to ensure the proper level is
achieved.
7. Install the filler / breather cap assembly.
8. Check the drain plug for leakage.
Changing The Hydraulic Fluid Filter
1. Turn off the engine and engage the parking brake.
2. Unscrew the oil filter cartridge from the mount and
discard in an approved manner.
3. Apply a thin coating of fluid to the seal of a new
filter element.
4. Thread onto the mount and hand tighten.
5. Tighten an additional one-half turn beyond hand
tight.
NOTE: Do not over tighten.
6. Start the machine, shut it off, then check for
leakage.