EN
CONTrOL
2101_EN_Steuerung_2310
- 26 -
Belt position indicator: here: field transport
with increased ground clearance
TIP
With increased ground clearance, the
machine is more than 4 m high.
•
Only drive in the field with
increased ground clearance
and never any further than
necessary.
•
Be aware of your surround-
ings when the ground
clearance is increased. For
example, high-voltage and
telephone lines, eaves or
trees.
Running direction of the belts to the right
or to the left
If the arrow flashes, the direction is
preselected and the belt is not running.
If the arrow is visible throughout, the
belt is moving in the indicated direction.
Automatic lift (active = green) /(inactive
= yellow)
Automatic belt system (active = green) /
(inactive = yellow)
Area worked in ha
Operating speed in ha/hr. (ha/hr is only
displayed if a speed signal is present).
keys:
STOP - with this key you stop all hydraulic
functions.
Return - with this key you return to the last
menu level - Here: Start menu
Centre swath key - Both belts running to the
centre (active: green / inactive: black)
Outside swath key - Both belts running to
the outside (active: green / inactive: black)
Side swath left key - Both belts running to the
left (active: green / inactive: black)
Side swath right key - Both belts running
to the right (active: green / inactive: black)
Left side preselection key - Press the key to
preselect the left side for lifting.
Use the control unit to raise/lower the
relevant side.
TIP
On the Expert 75 terminal, the key is shown
in green when the side is preselected.
Right side preselection key - Press the key
to preselect the right side for lifting.
Actuate the control unit to raise/lower the side.
TIP
On the Expert 75 terminal, the key is shown
in green when the side is preselected.
Automatic lift key (active = green) /(inactive
= yellow)
If the automatic lift is active, the second belt
unit is automatically preselected after the first
belt unit has been lifted, so that the second
belt unit only has to be moved with the control
unit. An acoustic signal is emitted after the
first belt unit has been lifted. In this way, it
allows the automatic lift to be moved out of
the field easily. An automatic sequence ends
when both belts are in the headland position.
Requirement:
- Machine is in working position
- No side has been preselected. Deselect
last side used.
Implementation:
1. Activate automatic lift
2. Set red control to "Lift" to raise the
preselected belt unit until the acoustic
signal sounds.
3. Set the red control unit to the float position
to ensure ground adaptation until the
second belt unit is raised.
4. Set red control to "Lift" to raise the
preselected belt unit.