Commissioning
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 85
7.2.1.1
Align transmitter
One of the adjustment templates supplied can be used to align the transmitter.
Magnet
Alignment grid
Magnet
Back gauge with notch
Cross-hair
The adjustment templates differ in the way the cutouts are arranged. It does not matter
which adjustment template you select for the transmitter.
Alternatively you can use an adjustment template that is screwed to a bracket. Installation
is described at the end of this chapter.
}
Attach an adjustment template with magnets to the upper tool. The tip of the upper tool
must sit in the notch on the stop of the adjustment template.
Align the alignment grid of the adjustment template to the contour of the upper tool.
Align the
alignment grid
on the upper
tool
Centre point of
the upper tool
in the notch on
the back stop
Fig.: Attach the adjustment template to the transmitter
}
The illuminated target area must completely envelop the receiver. If you hold a white
sheet of paper behind the receiver you will be able to see the contours of the receiver
better.